My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-09-01_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
1992-09-01_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2021 5:17:51 AM
Creation date
11/21/2007 10:49:25 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
9/1/1992
Doc Name
QUALITY ASSURANCE/QUALITY CONTROL-PROTOCOLS FOR THE COLLECTION OF SURFACE AND GROUND WATER
Type & Sequence
TR6
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />SECTION 6: PROTOCOL FOR ANALYSIS OF POROUS CUP LYSIMETER SAMPLES <br />AND PROCESS SAMPLES <br />' 6.1 Sample AvailaUility <br />' The nature and operation of the porous cup lysimeters dictates that <br />there are three conditions which apply to samples collected for <br />analysis: <br />(1) There is insufficient sample to perform any analysis: <br />' i.e. less than the minimum sample volume of 100 mis <br />required to perform and quantify appropria$ely QA/QC <br />compatible total cyanide analysis, assuming the <br />autoanalyzer method is used (see Section 6.3); <br />' (2) There is insufficient sample to perform other analyses <br />apart from total cyanide analysis; <br />1 <br />(3) There is sufficient sample to perform the full analysis <br />of the parameters listed on Table 2, including all QA/QC <br />requirements. <br />' In the case of condition 1, insufficient sample for total cyanide <br />' analysis, no analyses will be performed. A report will be issued <br />stating that there was insufficient sample for total cyanide <br />' analysis and quantification, including QA/QC requirements. <br />Where there is sufficient sample for the total cyanide analysis <br />alone, condition 2, this analysis will be done accordimq to the <br />procedures described in Section 6.3 and a report on iChe data, <br />' including the QA/QC report, will be issued. <br />' In the case of condition 3, where there is sufficient simple for <br />analysis of all parameters listed in Table 2, the procedures will <br />' -39- <br />
The URL can be used to link to this page
Your browser does not support the video tag.