<br />^ Immediately after collection, all samples must be placed in iced <br /> coolers. The sample bottles required for each sample site are <br />' listed in Table 5 (metals, cyanide). Sample preservation, pre- <br /> treatment and holding times, as outlined in Table 5, will be <br />' strictly adhered to. <br />t 4.2.7 Sample Filtration: Process samples requiring on-site filtration <br />will be filtered through a 0.45-micron filter. <br />' Samples will be preserved directly following filtration. <br />' Filter apparatus will be cleaned by having the solutions "pulled" <br />through the apparatus prior to and after each use in the following <br />' manner: <br />1 (1) mild non-phosphatic detergent wash; <br />(2) tap water rinse; and <br />' (3) final rinse with de-ionized water. <br />Following a filtration series of no more than 10 sample, a rinse <br />blank will be collected from the cleaned apparatus or, if <br />applicable, through an un-used filter cartridge, by running <br />' laboratory-provided de-ionized, distilled water throughout the <br />entire filtering apparatus. Analysis of this rinse blank will be <br />' used to validate cleaning procedures. <br />' 4.3 Record Keeoina <br />' All field data will be recorded in the Field Data Collection <br /> Sheets. These data will include: weather conditions, Volume of <br /> water removed from the lysimeter, lysimeter designation or <br />' h <br />l <br />ti t <br />th <br />hi <br />h th <br />l <br />k <br />i <br /> oca <br />on, t <br />e sequence es were <br />en, <br />e <br />n w <br />c <br />e samp <br />a <br /> sampler's name and the condition of the lysimeter. A Field Data <br />' Collection Checklist will also be filled out for each sample site <br />' 32 <br />