My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-11-01_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
1992-11-01_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2021 6:22:23 AM
Creation date
11/21/2007 9:02:06 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
11/1/1992
Doc Name
QUALITY ASSURANCE QUALITY CONTROL PROTOCOLS FOR THE COLLECTION OF SURFACE & GROUND WATER QUALITY DA
Type & Sequence
TR6
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
~~~,~ COAE LABOF3ATOg1E5 <br />' ~ryrastern Atlpe <br />International <br />.,,a.o~.c .o.~ <br />' r i r I F <br />ANALYTICAL CHEMISTRY DIVISION QUALITY ASSURANCE MANUAL <br />SOP ND. REVISIDN N0. EFFECTIVE DATE PAGE <br />HC-QAC-02 0 1/06/92 80 of 104 <br />when sample extractions for semivolatiles, pesticides or herbicides are <br />performed. <br />Extraction Blanks <br />Extraction blanks must be analyzed every time samples are extracted. This <br />extraction blank must be the same matrix type as the samples being <br />' processed. Purified silica sand may be used as an extraction material for <br />soiUsludge matrices. <br />' InitiallContinuing Calibration Verification <br />An initial calibration must be performed every time that a GC column is <br />' replaced, the mass spectrometer source is cleaned or repaired, or any time <br />major modifications are made to the instrument system. Daily calibrations are <br />required to verify proper equipment operation prior to sample analysis. If the <br />' daily calibration verification does not meet method-specified acceptance <br />criteria, a new initial calibration must be performed. Acceptance criteria for <br />intial and continuing calibration verifications are provided in the applicable. <br />1 analytical method. <br />' Svstem Performance Standard i <br />GC/MS system performance check standards (tuning compovlndsl must be I <br />' analyzed daily for volatile and semivolatile analyses. <br />Surrogate Recoveries <br />' Surrogates are required for volatile, semivolatile, pesticide, and herbicide <br />analyses. <br />' Surrogate recoveries must meet the method-specified QC limits. When <br />surrogate recoveries do not meet the method-specified criteria, that sample <br />' must be reanalyzed. If surrogate recoveries on the reanalysis still do not meet <br />method-specified limits, a probable matrix interference problem exists, and the <br />sample data should be qualified as estimated. Do not report these results <br />until the data has been reviewed and approved by the laboratory section <br />supervisor or the QA/QC coordinator. <br />t <br />
The URL can be used to link to this page
Your browser does not support the video tag.