Laserfiche WebLink
~ ~ <br />' SECTION 2: PROTOCOL FOR WATER SAMPLE HANDLING AND <br />GROUND WATER SAMPLE COLLECTION <br />' 2.1 Water Sample Handling and Mana~entent <br />I <br />Water sample handling and management will be conducted in <br />' accordance with the following procedures. <br />' 2.1.1 Receive Sample Containers. Laboratory Water and Coolers from Laborator <br />These items, when received, will be checked by the field sampling <br />' personnel to verify that they are in compliance wi1~h project <br />specifications. Empty sample containers and laboratory water will <br />be received in coolers. Achain-of-custody form will be received <br />with the above-mentioned items. Laboratory de-ionized water <br />provided with the sample bottles, and the sample containers, will <br />be enumerated on the chain of custody. After these items have been <br />checked and found to be in compliance they will be replaced into <br />the cooler. <br />' 2.1.2 Collect Samples and Record Field Data: Samples will be collected in <br />accordance with site-specific protocols as defined in Sections 2.2, <br />' 3.2 and 4.2. Field data will be recorded at the time of sample <br />collection on the Field Data Collection Sheet (Appendix B). <br />' Immediately after a sample is collected, sample identific&tion will <br />be recorded on the sample container (and on the Field Data <br />Collection Sheet) and this container will then be placed in an iced <br />cooler. If, at any point, there is a deviation from sample <br />collection protocols as outlined in the above-referenced sections, <br />these deviations must be noted on the chain of custody and in the <br />field book. <br />1 <br />-5- <br /> <br />