Laserfiche WebLink
i~ •~.: • • <br />I RESPONSE: Sampling deviations will be noted on the chain-of-custody form and will be <br />reported to the CMLRD, as necessary. <br />10. [No response required,) <br />11. [No response required.) <br />12. (No response required.] <br />13. jNo response required.) <br />i 14. [No response required.) <br />15. [Comment partially answered). Dr. Hyatt's comments addresses, in part, <br />aeration during sampling. BMRI should commit to collecting the sNmples in ways <br />that will minimize agitation during collection. <br />RESPONSE: BMR agrees that sample agitation will be minimized as much as is reasonably <br />possible. <br />16. [No response required.) <br />17. [No response required.) <br />18. [No response required.) <br />19. [No response required.) <br />20. The Division understands that BMRI wilt report routine analyses of WAD <br />Cyanide, Total Cyanide, and metals and calculate true WAD and Free Cyanide <br />according to the methods proposed by ASCI. If this is incorrect, BMRI should <br />specify details in this section. <br />RESPONSE: The Division's understanding in this matter is correct. <br />21. [No response required.) <br />-10- <br />