Laserfiche WebLink
June 2003 <br />TABLE 1 <br />SUMMARY OF EARTHWORKS MATERIAL SPECIFICATIONS <br /> <br />003-2203.7 <br /> Pl <br />i <br />i bili <br />P Grain Size Distribution <br /> ast <br />c <br />ty ty <br />ermea <br />Material Sieve Percent <br /> Index (cm/sec) <br /> Size Passin <br />Underdrain Fill NP N/A 12" 100 <br />(UF) No. 200 0-6 <br />Select Structural Fill N/A N/A 3" 100 <br />(SSF) <br />Leak Detection Fill NP N/A 3/4" 100 <br /> <br /> No.4 5-50 <br /> No. 40 0-20 <br /> No. 200 0-10 <br />Structural Fill 30 maximum N/A 24" 100 <br />(SF No. 200 0-25 <br />Soil Liner Fill 10 minimum 1 x 10~ 2" 100 <br />(SLF) No. 200 15-50 <br />Bedding Fill NP N/A 1" 100 <br /> <br /> No.4 5-55 <br /> No. 200 0-10 <br />Low Volume Solution NP N/A I" I00 <br />Collection Fill 3/8" 40-70 <br />(LVSCF) No.4 5-55 <br /> No. 200 0-10 <br />Drain Cover Fill NP N/A 1-1/2" 100 <br />(DCF) 3/4" 70-100 <br /> No.4 5-50 <br /> No. 200 0-8 <br />Select Drain Cover Fill N/A N/A 1" 100 <br />(SDCF) No. 200 0-5 <br />Coazse Shaft Backfill 20 maximum N/A 12" 100 <br />(CSB) No. 200 0-15 <br />Fine Shaft Backfill 5 maximum N/A 2" 100 <br />(FSB) 3/4" 70-100 <br /> No. 40 20-50 <br /> No. 200 2-15 <br />Notes: <br />1. Point Load Tensile Strength 5 300 psi for the underdrain fill. <br />2. NP =Non-plastic <br />3. N/A =Not applicable <br /> <br />Golder Associates <br />t.\OOS2201\pa00WnICmPSSA060J\Tables\TLxlsTl <br />