My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV11400
DRMS
>
Back File Migration
>
Revision
>
REV11400
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 1:22:22 AM
Creation date
11/21/2007 10:22:52 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977215
IBM Index Class Name
Revision
Doc Date
5/22/1998
Doc Name
BULLDOG MINE RECLAMATION PROJECT 9360 LEVEL ADIT CLOSURE MONITORING PLAN
From
HOMESTAKE
To
DNR
Type & Sequence
TR7
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' , <br />Adit plug construction monitoring 5 <br />1 <br />2.1.2 Infiltration french influent rate <br />' During times when adit seepage is directed to the infiltration trench, the influent rate to the trench <br />will be measured daily. The influent rate is to be measured using a 60° V-notch weir. The weir is <br />' mounted in the middle of a rectangular box to allow for accurate measurement of the height of <br />flow over the weir. To obtain accurate flow estimates, the height measurement will be taken <br />directly upstream of the V-notch. The influent box for flow measurement may require modification <br />' to address seasonal cold weather conditions. In any event, flow measurement will be provided. <br />' 2.1.3 Infiltration trench standpipe waterlevel <br />The infiltration trench is equipped with two standpipe piezometers, SP-1 and SP-2, to allow for the <br />' measurement of the water flow depth in the trench. SP-1 is located within 30 ft of the trench inlet <br />and SP-2 is located within 30 ft of the end of the trench. During operation of the infiltration trench, <br />water level measurements in each standpipe will be made daily. <br />' 2.1.4 Vadose zone piezometer water levels <br />Two vadose zone piezometers, VP-1 and VP-2, are installed adjacent to the infiltration trench to <br />monitor groundwater levels downyradient of the trench. VP-1 is located approximately 245 ft <br />' from the trench inlet and about 30 ft from the trench centerline. VP-2 is located approximately <br />200 ft from the downstream end of the trench and about 25 ft from the trench centerline. <br />During operation of the infiltration trench, water levels in the vadose zone piezometers are to be <br />' measured weekly. <br />' 2.1.5 Visual inspection o(the infiltration trench <br />In addition to water level monitoring in the standpipes and the vadose zone piezometers, the <br />' performance of the infiltration trench will also be monitored through visual inspection. Depending <br />on weather conditions, the visual inspection will be performed to detect possible saturated ground <br />adjacent to the trench and in the vicinity of the 9360 Portal. <br />' During operation of the trench during this monitoring period, the inspection will be made daily. <br />The inspection will be made only if the ground is not already saturated with precipitation or <br />' covered with snowfall. Should saturated ground conditions be detected, it is to be noted and <br />appropriate measures will be taken to remedy the situation. <br />2.2 Windy Gulch monitoring <br />' Windy Gulch water quality samples (WGWB) are to be taken monthly at the Windy Gulch weir, <br />which is located about 200-300 ft upstream of the confluence of Windy Gulch and Willow Creek. <br />Each sample will be gathered based on the procedures outlined in Attachment A. The samples <br />obtained will be analyzed for the parameters presented in Table 2.2 (see Section 2.1.1). Flow <br />' measurements, at the time of water quality sampling will be taken at this location, when practical. <br />Flows in Windy Gulch at this location will be estimated by measurement of the height of the water <br />over the weir or other suitable method with documentation of the method used. <br />
The URL can be used to link to this page
Your browser does not support the video tag.