My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV00811
DRMS
>
Back File Migration
>
Revision
>
REV00811
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 12:58:28 AM
Creation date
11/21/2007 8:48:09 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1982020
IBM Index Class Name
Revision
Doc Date
9/12/1985
Doc Name
LUCKY STRIKE MINE FN M-82-20
From
QUATERNARY ENVIRONMENTAL CONSULTING
To
MLR
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />A comparison of the lined pond as designed and constructed is given as <br />follows: <br />Design <br />Surface area of Pond <br />25,000 ft.2 <br />Triangular-shaped <br />Maximum Pond Depth <br />Liner <br />Fence <br />Warning Sign Interval <br />Pond Inslope <br />Pond Outslope <br />15 ft. <br />30 mil reinforced <br />hypalon keyed into <br />trench at crest. <br />6 ft. wire-mesh <br />As Built <br />23,000 ft.2 est. <br />Oval-shaped <br />15 ft, est. <br />30 mil reinforced <br />hypalon keyed into <br />trench at crest. <br />Most of the seams <br />were made using the <br />factory diaelectric <br />sealing process. <br />6 - 6,5 ft, wire- <br />mesh topped with 2 <br />strands barbed wire. <br />Locked access gate. <br />100 ft. 90 ft, max. Signs <br />measure 7 in. X 20 <br />in., state: "Danger <br />Cyanide" <br />- 2:1 - 2.5:1 <br />3:1 2.75:1 - 3.5:1 <br />The pond's leak-detection system and underliner are obviously not <br />exposed for observation. The operator reports that the underliner was <br />constructed of 1,5 to 2 feet of compacted clay covered with a 6 inch <br />minimum layer of sand and gravel. The pond's base slopes inward and an <br />aggregate drain was keyed into the clay sub-base near the center, bottom of <br />the pond. The drain serves to collect any possible leaks and incorporates <br />perforated PVC pipe, with filter cloth used to reduce the clogging <br />potential from fines translocated Erom above. A single vacuum test outlet <br />for the leak detection system exists on the south side of the pond, just <br />inside the access gate. <br />Tailings Pond <br />The stipulated analytical data for the discharge to the lower tailings <br />pond has been submitted to Skyline Laboratories but the results are not now <br />available. The will be forwarded under separate cover. Other details <br />regarding the construction of the pond are given below. <br />
The URL can be used to link to this page
Your browser does not support the video tag.