My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE72133
DRMS
>
Back File Migration
>
Permit File
>
800000
>
PERMFILE72133
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 11:21:39 PM
Creation date
11/21/2007 12:08:07 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083
IBM Index Class Name
Permit File
Doc Date
5/12/2003
Doc Name
Intro and Sections 1 thru 5 and 7 thru 8
Section_Exhibit Name
Volume VII Geotechnical Studies
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Morrison Knudsen Corporation <br />October 10, 1996 <br />Page 3 <br />(SF) of 1.7 and 1.9 for sections A-A and B-B, respectively. For the purpose of evaluating long- <br />term stability we also modeled conditions consisting of the phreatic surface at the ground surface <br />and of increased pore pressures. For these cases the SF ranged from 1.6 to 2.1, well above the <br />required value of 1.3. In general the stability of the reclaimed slopes is less sensitive to <br />variation in ground water or pore pressure and more dependant on the shear strength of the soil. <br />In general, the subsurface conditions modeled in the stability analysis were conservative. <br />Bedrock was modeled at an elevation of about 20 feet lower than that indicated from the borings. <br />The location of ground water was also modeled far more conservatively than what the borings <br />would suggest. In summary, we are of the opinion that although effective stress parameters <br />were not used, the resulting safety factors determined by this analysis are conservative and well <br />in excess of the required factor of safety of 1.3. We believe that if the reclaimed slopes are <br />properly constructed as described below, stability should not be a problem. <br />Fill Recommendations: Reclaimed fill slopes should be no steeper than 3:1 overall. All fills <br />should be placed on ground that is completely cleared of vegetation and root growth. Where <br />available, boulder rubble with a wide range of sizes would be acceptable for use as a starter fill <br />• at the toe of the fill. Where boulder rubble is used as a drainage feature beneath a Fill, it should <br />be protected from fines migration by either a filter fabric or a suitable filter course. If rubble <br />is placed in areas not intended for drainage, it is important the rock be irrcorporated into a soil <br />matrix to insure that any voids between rock are filled to prevent migration of fines. <br />Proper drainage of reclaimed fill slopes is critical to long-term performance. Any drainage <br />features located above the fill should be intercepted and diverted away from the fill. Any <br />surface water conditions that may develop on the cut slopes should be drained. The existing cut <br />slope benches could be used in conjunction with a drainage system. The face of the reclaimed <br />slopes should be properly revegetated and constructed to allow for adequate drainage to prevent <br />oversteepening of the slopes due to erosion. <br />We recommend the fill material be placed in horizontal lifts, adjusted to a moisture content at <br />or above optimum moisture and compacted to at least 85 % of the maximum modified Proctor <br />density. It is important that the reclaimed slopes be keyed into the existing cut slopes. Our <br />previous study recommended benching the cut slopes at intervals on the order of 8 to LS feet in <br />height. These existing benches may be used for placement of fill provided they are first cleared <br />of any sloughed or eroded material and properly prepared. We believe additional benches are <br />necessary to adequately key the fill for the reclaim slopes, We recommend additional benches <br />be cut every 4 to 5 feet of slope height. The benches should be at least 4 feet wide. The bench <br />surface should be prepared by scarifying to a depth of 8 inches, adjusting the moisture content <br />• to at or above optimum and compacting to at least 85% of modified Proctor density. <br />
The URL can be used to link to this page
Your browser does not support the video tag.