Laserfiche WebLink
<br />information garnered from the LDS (see Protocol _ below) to comply with Rule 8.0. <br />including notification of the OMLR within 24 hours of CC&V having knowledge of such <br />exceedences, a written discussion of precautions and corrective actions undertaken and planned <br />submitted to the OMLR, with a timetable for implementation, and a written report satisfying <br />Rule 8.2.3. Corrective actions will include a specific plan of corrective action to be timely <br />implemented to control, reduce, or otherwise minimize movement of leach solution in harmful <br />quantities moving outside the permit area. Though any such circumstance will necessitate case- <br />specific measures, CC&V will address testing of areas through manipulation of leach solution <br />application. [?At any time when redeployment of applied water has not mitigated the migration <br />of leach fluid from the pad to the environment, CC&V will cease addition of additional water <br />to the pad.?] <br />d. The results of laboratory analyses for the listed parameters will be provided to the OMLR <br />along with the sampling locations, date and time of sampling, type of analyses, and applicable <br />laboratory sample number. <br />TABLE 1 - 30-day Average Threshold Concentrations - Underdrain <br />PARAMETER UNTIL DECEMBER 31, AFTER DECEMBER 31, <br />CNW„p 1-0 mg/l 0.5 mg/I <br />pH 9.0 s.u. 9.0 s.u. <br />Leak Detection System (LDSI: If the CNw„o and pH in the LDS exceeds both of the values <br />listed in the following Table 2 and the flow criterion is met, CC&V shall undertake the <br />following steps: <br />~ H atut~ <br />a. Notify the OMLR by telephone within wer-ktftg-daps of having knowledge of the <br />combination of elevated water-quality parameters and sustained flow <br />b. The frequency of monitoring shall be increased to~ samples per 7 days until one or more <br />of the criterion concentrations listed in Table 2 are not exceeded or the flow criterion is not met <br />or until it is shown to the satisfaction of the OMLR that the increased frequency is not required <br />because pertinent information is not being generated. <br />c. If both of these centrations listed in Table 2 are exceeded for more than days, or if <br />the levels rise to <_mg/I CNWAp and _<9.5 s.u., and if the flow is consistent throughout the <br />intervening period, CC&V will consider there to be a defect in the active Cresson Valley Leach <br />Facility that allows CN-bearing solution from that facility to move into the surrounding <br />environment and will combine this information with the information garnered from the <br />Underdrain system (see Protocal _ above) to comply with Rule 8.0., including notification <br />of the OMLR within 24 hours of CC&V having knowledge of exceedences, a discussion of <br />3 <br />