Laserfiche WebLink
--- - ECILJIPMIENT SPEC7riC.aT10~J~^ <br />C <br />SECTION II <br />10.2 Each blower shall be capable of delivering 100 CFM when operacir.; ac <br />_ PSI. The blower shall be manufactured by Roots Division of :.resser <br />Industries, Inc., Connorsville, Indiana; or Sutorbilt Blower, Fuller <br />Company, Compton, California; or approved equal. The model number of <br />the blower will be 3 <br />10.3 The motor shall be horsepower for operation on 480 Volt, 3 Phase, <br />60 Cycle Service, 1750 RPM. It shall be of the open drip proof type. <br />SE <br />SYSTEM PAG2 5 <br />10.4 Each blower shall be mounted on a fiberglass (metal) base. The base <br />structure shall be adequately reinforced to support the blower and motor <br />unit. Furthermore, the base shall have a light blue finish. <br />10.5 For easy adjustment of the "V" belt drive connection between the blower <br />and notor, the motor will be furnished with an adjustable motor mouncinc; <br />base. <br />C <br />10.6 The blower shall be fitted with a dry type filter-silencer at the air <br />intake. Furthermore, the blower discharge shall be fitted with a check <br />valve when required, and a flexible rubber discharge coupling. <br />10.7 Each blower and motor shall be enclosed within a fiberglass (metal) <br />weatherproof enclosure. The fiberglass (metal) hood is designed for <br />easy access to service the unit. It shall be equipped with a lif;'_ng <br />handle and locking facilities. All enclosure surfaces shall be properl}• <br />prepared in a neat manner to obtain a smooch, clean and dry surface. <br />The enclosure shall have a light blue finish. ' <br />10.3 To help reduce blower vibration and noise, the blower motor enclosure <br />shall be mounted on vibration dampners. For purposes of deteraining <br />the blower performance, and/or diffuser condition, a pressure relief <br />valve and pressure gauge shall be mounted in the air manifold. <br />X 10.9 (Optional) Belt Cuard Ear the "V" belt drive unit shall be suppl_ad <br />attached to the blower mounting base. The belt guard shall be designed <br />for easy access to the sheaves of both the motor and blower. The pelt <br />guard shall be fabricated of metal and shall be painted OSIiA yel'_ow. <br />10.10 (Optional) A discharge muffler shall be installed on the dischar;a end <br />of the blower. The muffler shall be a model as manufactures by <br />Universal Silencer, Stoughton, ldisconsin; or approved equal. <br /> <br />11. ELECTRICAI. CONTROL CE`lTER <br />11.1 An electrical control center shall be installed within a weather~rcof <br />enclosure and shall be provided Eor mounting as indicated on the olans. <br />