Laserfiche WebLink
-~ Mr. Crellin Scott <br />July 30, 2002 <br />Page 3 of 3 <br />Based on the information provided by Colowyo Coal Company; the Stoker Pond meets <br />the (SCS) TR-60 classification criteria for a Class A Dam. The pond is located in an agricultural <br />area where failure is limited to damaging farm buildings; agricultural land, or county roads. <br />However, the dam classification system considers several factors that are objective (Earth Dams <br />and Reservoirs. Technical Release No. 60; Page 1-1). For example; consideration is given for <br />existing and future development and the effect of failure on public confidence. Future <br />development in the mountains of Colorado is difficult to predict. Dams are classified as Class B <br />Dams if failure may damage isolated homes, main highways or railroads or interrupt service of <br />relatively important public utilities. <br />As a Class A structure, the Stoker Pond is not necessarily required to meet the TR-60 <br />Emergency Spillway Evaluation and the TR-60 Emergency ',spillway Freeboard Evaluation <br />conditions (items 11 and 12 above). However, the SEDCAD 4 models demonstrate that the <br />Stoker Pond meets the criteria for a Class B structure. <br />C7 <br />SL:sb <br />Enclosures <br />cc: Dale Brown <br />File: 99-642 <br />i• <br />Sincerely, <br />Steve Linse, <br />Colorado P.E. 35009 <br />Project Engineer <br />W <br />WC Engineering <br />