My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE59030
DRMS
>
Back File Migration
>
Permit File
>
600000
>
PERMFILE59030
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 11:01:21 PM
Creation date
11/20/2007 6:06:03 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2002004
IBM Index Class Name
Permit File
Doc Date
3/27/2003
Doc Name
Condition #1
From
GCC Rio Grande Inc
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II <br />' SOP #: GW 0001 <br />Region I Low Stress <br />(Low Flow) SOP <br />' Revision Number: 2 <br />Date: July 30, 1996 <br />Page 7 of 13 <br />' measured within the cell and may also cause an underestimation of <br />turbidity values measured after the cell. If the cell needs to be <br />cleaned during purging operations, continue pumping and disconnect <br />cell for cleaning, then reconnect after cleaning and continue <br />monitoring activities. <br />' The flow-through-cell must be designed in a way that prevents air <br />bubble entrapment in the cell. When the pump rs turned off or <br />cycling on/off (when using a bladder pump), water in the cell must <br />' not drain out. Monitoring probes must be submerged in water at. all <br />times. If two flow-through-cells are used in series, the one <br />containing the dissolved oxygen probe should come first (this <br />parameter is most susceptible to error if air leaks into the system). <br />' S. Collect Water Samples <br />' Water samples for laboratory analyses must be collected before water <br />has passed through the flow-through-cell (use a by-pass assembly or <br />disconnect cell to obtain sample). <br />VOC samples should be collected first and directly into pre-preserved <br />' sample containers. Fill all sample containers by allowing the pump <br />discharge to flow gently down the inside of the container with <br />minimal turbulence. <br />During purging and sampling, the tubing should remain filled with <br />water so as to minimize possible changes in water chemistry upon <br />contact with the atmosphere. It is recommended that 1/4 inch or 3/8 <br />inch (inside diameter) tubing be used to help insure that the sample <br />tubing remains water filled. If the pump tubing is not completely <br />filled to the sampling point, use one of the following procedures to <br />collect samples: (1) add clamp, connector (Teflon or stainless <br />steel) or valve to constrict sampling end of tubing; (2) insert small <br />diameter Teflon tubing into water filled portion of pump tubing <br />allowing the end to protrude beyond the end of the pump tubing, <br />collect sample from small diameter tubing; (3) collect non-VOC <br />samples first, then increase flow rate slightly until the water <br />completely fills the tubing, collect sample and record new drawdown, <br />flow rate and new indicator field parameter values. <br />Add preservative, as required by analytical methods, to samples <br />immediately after they are collected if the sample containers are not <br />pre-preserved. Check analytical methods (e.g. EPA SW-846, water <br />supply etc.) for additional information on preservation. Check pH <br />for all samples requiring pH adjustment to assure proper pH value. <br />For VOC samples, this will require that a test sample be collected <br />during purging to determine the amount of preservative that needs to <br />be added to the sample containers prior to sampling. <br />If determination of filtered metal concentrations is a sampling <br />objective, collect filtered water samples using the same low flow <br />procedures. The use of an in-line filter is required, and the filter <br />
The URL can be used to link to this page
Your browser does not support the video tag.