Laserfiche WebLink
• Statistical Methods <br />Sample adequacy calculations were carried out using the formula prescribed by CMLRD (1988): <br />Nmin = <br />t2 s2 <br />d2 x2 <br />where: <br />t 1.645 (two-tailed t-value with infinite degrees of freedom at probability level 0.10) <br />s2 sample variance (based sn-1) <br />d = 0.1 (level of precision or desired detectable reduction) <br />x =sample mean <br />Comparison of Expansion Area cover to cover within the same types in the existing Seneca II-W Permit <br />Area was accomplished using the formula set forth on page 16 in CMLRD (1988). <br />Ix) - xil <br />• tc <br />~ sp2 / n) +sp2 / ni <br />where <br />x) = Expansion area cover sample mean <br />xi Permit area cover sample mean <br />n) = Expansion area sample size <br />ni Permit area sample size <br />tc Calculated t value <br />(n) -1) (s2)) + (ni -1) (s2i) <br />sp2 =Pooled sample variance = <br />1 ~ <br />Floristic Analysis <br />. All plants observed during field studies were noted, and where any question as to their identity existed, <br />4 <br />