Laserfiche WebLink
PART I <br />Page vii <br />Permit No. CO-0000213 <br />A. TERMS AND CONDITIONS <br />3. Salinity Parameters <br />In order to obtain nn indication of the quantity of Salinity being discharged from the site, the permittee shall monitor the <br />wastewater effluent at the following frequencies: <br />Outfal I Frequency <br />001, 1102, 003, 004, 005, 1106, 007 Quarterly <br />Sample Tvoe <br />Grab <br />Self-monitoring samples taken in compliance with the monitoring requires specified above shall be taken at those <br />locations listed in Part I.B.1. <br />B. MONITORING REQUII2EMENTS <br />1. Freauencv and Sample Tvoe <br />Tn order to obtain en indication of the probable compliance or noncompliance with the effluent limitations specified in <br />Part I.A.1, the permittee shall monitor all effluent parameters at the following frequencies. Such monitoring will begin <br />immediately and last for the life of the permit unless otherwise noted. The results of such monitoring shall be reported <br />on the Discharge Monitoring Report (See Part i.B.2.) <br />(a) Outfalls 002. 003. 004. 005 and 006 <br />Ellluent Parameter Measurement Freauencv Sample Tye <br />Flow, MGD Monthly Instantaneous <br />or Continuous <br />Settleable Solids, mllP Monthly Grab <br />Oil and Grease, mg/P Monthly Visual <br />pH, s.u. Monthly Grab <br />(b) Outfalls 001 and 007 <br />Effluent Parameter Measurement Frequency Sample Tvue <br />Flow, MGD Weekly Instantaneous <br /> or Continuous <br />Total Suspended Solids, mg/P Monthly Grab <br />Total Iron, mg/P Monthly Grab <br />Settleable Solids, mP/P Monthly Grab <br />Oil and Grease, mg1P Weekly Visual <br />pH, s.u. Weekly Grab <br />Whole Effluent Toxicity, Acute <br />Outfall 001 Annually Grab <br />Outfal1007 Quarterly Grab <br />Self-monitoring sampling by the pennittee for compliance with the monitoring requirements specified above shall be <br />performed at the following locations: Outfalls 001, 002, 003, 004, 005, 006 and 007 - at the outfalls from the final <br />ponds, prior to entering the receiving waters. <br />If the permittee, using the approved analytical methods, monitors any parameter more frequently than required by <br />this permit, then the results of such monitoring shall be included in the calculation and reporting of the values <br />required in the Discharge Monitoring Report Form or other forms as required by the Division. Such increased <br />frequency shall also be indicated. <br />See Parl I.C. for Definitions. <br />wont ai9iv3 <br />