My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE53380
DRMS
>
Back File Migration
>
Permit File
>
600000
>
PERMFILE53380
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 10:56:50 PM
Creation date
11/20/2007 3:45:04 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Permit File
Doc Date
9/3/2002
Doc Name
Certification of Report Phase IV
From
Cripple Creek & Victor Gold
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2002 -22- 003-2203 <br />. 50,000 cubic yazds. The CQA gradations of SSF met project specifications. The SSF CQA <br />gradation results aze presented in Appendix I-1 and summarized in Table 6. <br />Golder performed 1 CQA gradation of LDF. The testing frequency (approximately one test per <br />84 cubic yazds) exceeded the minimum specified testing frequency of one test per 10,000 cubic <br />yards. The CQA gradation of LDF met project specifications, The LDF CQA gradation results <br />aze presented in Appendix I-1 and summarized in Table 7. One LDF test failed to meet <br />specifications. The LDF was removed and replaced with LDF meeting the project <br />specifications. <br />Golder performed I 1 CQA gradations of SF. The testing frequency (approximately one test per <br />40,090 cubic yazds) exceeded the minimum specified testing frequency of one test per <br />50,000 cubic yazds. The CQA gradations performed on SF met project specifications. The SF <br />CQA gradation results aze presented in Appendix I-1 and summarized in Table 8. <br />• Golder performed 12 CQA gradations of SLF. The testing frequency (approximately one test <br />per 4,413 cubic yazds) exceeded the minimum specified testing frequency of one test per <br />5,000 cubic yards. The CQA gradations performed of SLF met project specifications. The SLF <br />CQA gradation results are presented in Appendix I-1 and summarized in Table 9. <br />Golder performed 6 CQA gradations of DCF. The testing frequency (approximately one test <br />per 17,653 cubic yards) exceeded the minimum specified testing frequency of one test per <br />20,000 cubic yazds. The DCF CQA gradations met project specifications, and the results aze <br />presented in Appendix I-1 and summarized in Table 10. <br />Golder performed 1 CQA gradation of FSB. No testing frequency was identified in the CQA <br />Plan for this material. The CQA gradation performed on FSB met project specifications. The <br />FSB gradation results aze presented in Appendix I-1 and summarized in Table 11. <br />• <br />I:~omzzo3~aaomCeMryo9oz~0012xo3.0ao0.0a]aotxt doc Golder Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.