Laserfiche WebLink
2002 -20- 003-2203 <br />i 4.0 EARTHWORK CQA TESTING AND MONITORING <br />The following sections summarize results of the earthwork CQA testing and monitoring <br />performed by Golder for the Phase IVa Area. <br />Golder conducted CQA testing of earth materials used for construction. Golder performed <br />CQA testing of in-place materials used for construction of the Phase IVa Area. Table 4 <br />presents specified and observed CQA testing frequencies. Figure 1 shows the coordinate <br />system used to locate tests. <br />In accordance with the Golder CQA Plan, when a Golder monitor observed deficiencies, the <br />monitor detemuned the nature and extent of the problem and notified Ames and/or CC&V. <br />When unsatisfactory test results identified a deficiency, Golder performed additional tests to <br />define the extent of the deficient azea. Ames corrected deficiencies to meet the requirements of <br />• the specifications, and Golder retested and/or approved the corrected deficiency prior to any <br />additional related work. The following sections include discussions of the deficiencies <br />encountered. <br />4.1 Results of Laboratory Soils Testing <br />Golder performed laboratory testing of soils during ali aspects of the Phase IVa construction. <br />Golder's soils laboratory in Lakewood, Colorado performed permeability and bulk specific <br />gravity testing of SLF. All other testing was performed on-site. To verify that the earth <br />materials used during construction met project specifications, Golder performed the following <br />American Society for Testing and Materials (ASTM) tests: <br />- Rock corrected density values (ASTM D4718); <br />- Grain size distribution (ASTM D1140 for material finer than the No. 200 <br />• sieve, and ASTM C117 and C136 for coarse material); <br />~~~:o3~oaoo~c~POeoz~ooaazo3oaoooa~nouieoc Golder Associates <br />