Laserfiche WebLink
Y • • <br /> STATE OF COLORADO <br />DIVISION OF MINERALS AND GEOLOGY <br />Depanmenl of Natural Resour ces <br />I l l l Sherman St.. Room ? I S `a <br /> <br />Denver, Colorado AO?OJ I <br />~~ <br /> <br />Nhnne IJll3)866~3567 II <br />FAX: 1311}I 8}'-8106 <br /> DEPARTMENT OF <br /> NATURAL <br /> RESOURCES <br /> Roy Romer <br />DATE: September 28, 1995 cOVe`°°` <br /> lames 5 Eochhead <br /> E.ecmive Dueno, <br />TO: Bruce Humphries Micnael f3. fnnR <br /> <br />FROM: Divisi°n Dirttmr <br />Berhan Keffelew <br /> <br />RE: Temporary Baseline Data Compilation to Set Trigger Parameters for pH, WAD <br /> Cyanide, and Volume for LDS I-V, Underdrain Discharge and Ground Water <br /> Monitoring Wells, Permit No. M-80-244, Cresson Project, Phase I <br />As you requested I have complied the data provided by CC & VG on Friday the 8th of <br />September since Mr. John Hardaway has expressed some reservations about the CDQH & E labs <br />data provided by CC & VG was utilized for this report. Based on the data attached, the <br />following conditions should be placed to modify commitments 24, 30, and 31. <br />Condition No. 1 <br />a. If the parameters described for Arequa Gulch underdrain in the table titled "30 Day <br />Average parameters and Standards that Trigger an Emergency Response by the Permittee" <br />are exceeded, then the permittee must conclude that a "failure or imminent failure" (loss <br />of containment of cyanide solutions) has or is about to occur for emergency response <br />purposes. The 30 day average for the underdrain is greater than .5 WAD cyanide - 8.5 <br />pH (no volume standard). If the 30 day average for the LDS is greater than 5 WAD <br />cyanide 8.5 pH, and less than 28 gallons/day. <br />b. If cyanide concentrations at any of the ground water monitoring points in Arequa or <br />Wilson Gulches exceed the parameters described in the table titled "30 Day Average <br />Parameters and Standards that Trigger an Emergency Response by the Permittee", then the <br />permittee must conclude that a "failure or imminent failure" (loss of containment of <br />cyanide solution) has or is about to occur for emergency response purposes. For the GW <br />monitoring wells, the WAD cyanide is greater than .2 mg/I and greater than 8.5 pH (no <br />volume standard). <br />c. If either (a) or (b) occur, the permittee shall notify the Office according to the provisions <br />of Rute 8.1, and 8.2. In addition to the requirements of Rule 8.2.2, the notice shall <br />include copies of the actual laboratory analyses report data sheets, the date samples were <br />collected, the sample points sampled, the method of sample preservation, and the name <br />of the person that collected the samples. <br />