My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO23029
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO23029
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:43:43 PM
Creation date
11/20/2007 3:28:04 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981041
IBM Index Class Name
Hydrology
Doc Date
5/9/1994
Doc Name
RATIONALE FOR PUBLIC NOTICE PN CO-0027146
Permit Index Doc Type
NPDES
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PART I <br />Page if of 19 <br />Permit No. CO-0027146 <br />B. MONITORING REQUIREMENTS <br />3.. Reporting of Data (continued) <br />The first on ig pal copy of each discharge monitoring report (DMR) shall be submitted <br />to the Division at the following address: <br />Colorado Department of Health <br />WQCD-PE-B2 <br />4300 Cherry Creek Drive South <br />Denver, Colorado 80222 <br />The first duplicate signed copy of each report form shall be submitted to the following <br />agency: <br />U.S. Environmental Protection Agency <br />Water Management Division <br />NPDES Branch 8WM-C <br />999 18th Street, Suite 500 <br />Denver, CO 80202-2466 <br />4. Acute WET Testine - Outfalls 001. 002. 004 and 015 <br />(a) Testing and Reporting Repulrements <br />Tests shall be done at the frequency listed in Part I.B.l. Test results shall <br />be reported along with the Discharge Monitoring Report (DMR) submitted for the <br />reporting period during which the sample was taken. (i.e., WET testing results <br />for the first calendar quarter ending March 31 shall be reported with the DMR due <br />April 28.) The results shall be submitted on the Acute Toxicity Test report <br />form, available from the Division. Copies of these reports are to be submitted <br />to both the Division and EPA along with the DMR. <br />The permittee shall conduct each acute WET test in general accordance with <br />methods described in Methods for MeasurinE the Acute Toxicity of Effluents and <br />Receiving Waters to Freshwater and Marine Organisms, EPA/600/4-90/027 or the most <br />current edition, except as modified by the most current Division guidance <br />document entitled Guidelines for Conducting Whole Effluent Toxicity Tests. The <br />permittee shall conduct an acute 48-hour WET test using Ceriodaphnia sp., and an <br />acute 96-hour WET test using fathead minnows. Acute tests will be replacement <br />static tests of a single effluent grab sample. <br />(b) Failure of Test and Division Notification <br />An acute WET test is failed whenever the LCSO, which represents an estimate of <br />the effluent concentration which is lethal to SOX of the test organisms in the <br />time period prescribed by the test, is found to be less than or equal to 100X <br />effluent. The permittee must provide written notification of the failure of a <br />WET test to the Division, along with a statement as to whether the Preliminary <br />Toxicity Incident ("PTI")/Toxicity Identification Evaluation ("TIE") <br />investigation or accelerated testing is being performed (see next section). <br />Amendment No. 1 Issued Effective <br />
The URL can be used to link to this page
Your browser does not support the video tag.