Laserfiche WebLink
PART 1 <br />Page v <br />Permit No. CO-0042161 <br />B. MOI•fITORING REQUII2EMENTS <br />1. E'reguencv and Sample Tvpe <br />hi order to obtain an indication of the probable compliance or noncompliance with the effluent limitations specified in Pan <br />I.A.I., the permittee shall monitor all effluent parameters at the following frequencies. Such monitoring will begin <br />immediately and last for the life of the permit unless otherwise noted. The results of such monitoring shall be reported on <br />dte Dischazge Monitoring Report (See Pan I.B.2.). <br />(.t) Outfal1001 <br />Effluent Parameter <br />Flow, MGD <br />Total Suspended Solids, mg/Q <br />Total Rectrverable Iron, mg/P <br />Oil and Grease, mg/P <br />pH, s.u.*" <br />Total Dissolved Solids, mg/Q <br />Dissolved Aluminum, mg/P <br />Total Awnonia as N, mg/P <br />Whole Effluent Toxicity, Chronic <br />Measurement Freauencv Sample T~~pe <br />Weekly Instantaneous <br /> or Continuous <br />Monthly Grab <br />Monthly Grab <br />Weekly Visual <br />Weekly Grab <br />Quarterly Grab <br />Montlily Grab <br />Monthly Grab <br />Qtarterly 3 Composites/Test* <br />• 'ILe pe nnittee may collect two composite samples when discharge is imetmitten[, with samples collected on consecutive days of discharge. <br />•• "ILe permittee shall also monitor pH m Fish Creek immediately above outtall fql and below oudall (pl at a point after mixing but prior to any other source <br />enteriq; the creek. <br />Qt) Clutfall002 <br />Effluent Parameter Measurement Freauencv Sample Tvpe <br />Flow, MGD Weekly Instantaneous <br />or Continuous <br />BODs, mg/P Monthly Grab <br />Total Suspended Solids, mg/Q Monthly Grab <br />Fecal Coliform, No./100 mP Monthly Grab <br />(r) Point 3001 (influent) <br />Imfluent Parameter Measurement Freauencv Sample Tvpe <br />Flow, MGD Weekly Instantaneous <br />or Continuous <br />BCIDs, mC;/P Montlily Grab <br />Self-monitoring sampling by the permittee for compliance with the monitoring requirements specified above shall be <br />performed at the following locations: Outfall 001, prior to entering Fish Creek; Outfall 002, the point of dischazge at the <br />effluent weir in the control building, prior to entering Emerald Spring (a spoils spring); Point 3001 (influent) samples shall <br />be collected prior to entering the first aerated lagoon. Influent samples shall be collected at the specified frequencies <br />r~:ttardless of whether a dischar¢e occurs durin¢ the applicable period. Instream pH samples described by ** shall be <br />collected at the same time and at the same frequency as required for outfall OOI. <br />If the pertnittee, using the approved analytical methods, monitors any pazameter more frequently than required by this <br />permit, then the results of such monitoring shall be included in the calculation and reporting of the values required in dte <br />Clischazge Monitoring Report Farm or other forms as required by the Division. Such increased frequency shall also be <br />indicated. <br />See Part Q.C. for Definitions. <br />Amendment No. ]Issued Effective <br />