Laserfiche WebLink
• <br />~~ <br />TABLE 2 <br />SOIL CONSTRUCTION TESTING FREQUENCY <br />VOLUME PER TEST' <br />1. Tests shall be performed at the specified frequency or one per material type, whichever is greater. <br />2. Use the USCS for description and identification (ASTM D2488). <br />3. In-place Moisture Content. <br />4. If the permeability of Soil Liner Fill is higher than 9.0x10"~ cm/sec, an additional permeability test will <br />be performed on a sample located within a 10 foot radius of the sample in question. If the permeability <br />of the Soil Liner Fill is higher than 1.Ox10"* cm/sec, 4 additional samples will be obtained from with <br />135,000 squaze foot azea centered about the failing test. This testing sequence will be repeated if <br />additional failing permeability tests aze measured. <br />*** END OF SECTION *** <br /> <br />Section 01400.1 Page 10 of ] 0 <br />Earthworks CQA Plan Golder Associates <br />two~zzo~waao~cFlernEroaoa~neeerroswreea ~aootrts.noc <br />March 22, 2000 <br />Revision 5 <br />