Laserfiche WebLink
<br />• <br />i• <br />TABLE 1 <br />SOIL CONSTRUCTION TESTING FREQUENCYI <br />VOLUME PER TEST <br />Compaction <br />(ASTM D698) <br />Particle Size2 <br />(AST'M C117, C136, <br />D1140) <br />Atterberg Limit <br />(ASTM D4318) <br />Moisture Content' <br />(ASTM D2216) <br />Nucleaz Density <br />(ASTM D2922) <br />50,000 50,000 50,000 - <br />50,000 50,000 50,000 5,000 <br />- 50,000 - 5,000 <br />2,000 2,000 2,000 5,000 <br />2,000 2,000 2,000 - <br />1. Tests shall be performed at the specified frequency or one per material type, whichever is greater. <br />2. Use the USCS for description and identification (ASTM D2488). <br />3. In-place moisture content. <br />Section 01400.1 Page 9 of 10 <br />Earthworks CQA Plan Golder Associates <br />1:\W\2203\0400\CER]REPo802UPPENDSpPPE\01400I RS.~OC <br />Mazch 22, 2000 <br />Revision 5 <br />