• TECHNICAL REVISION N0. 14 <br />Response: <br />The Pond 008 Diversion Ditch is only proposed to be a short-term <br />diversion used to control runoff until proposed Sedimentation Pond 009 <br />is permitted and constructed by the end of 1989. Sedimentation Pond 008 <br />was designed assuming all of the runoff from the watershed would flow <br />into 008; however, this is conservative and until 1990, there will be an <br />open pit, a minimum of four spoils and various haul road ramps which may <br />intercept the runoff and detain the runoff in the upper part of the <br />watershed. Therefore, the additional 42.9 acres contained in this <br />diversion ditch would be offset by the pits, spoils and haul road ramps <br />which occur in the 008 watershed. The 42.9 acres represents "worst <br />case", assuming part of the Wadge Scraper Pit ditch area within the <br />mining area was also included. The most probable watershed would only <br />be below the Wadge Scraper Pit or 17.8 acres; however, for design <br />purposes on the 008 North Ditch, the 42.9-acre watershed was used. In <br />addition, an analysis was performed using the Sedimentation Pond 008 <br />as-built input data and adding the 42.9 acres in the ditch's watershed <br />to the Pond 008 watershed for a total of 290.44 acres (see the attached <br />analysis for the 10-year, 25-year and 100-year precipitation event). <br />The rest of the input data was used as is. The results indicate no <br />change in the basin trap efficiency for the 10-year, 24-hour storm. The <br />peak stage is increased less than 0.5 ft for all three storms and <br />• adequate freeboard remains on Pond 008. The peak spillway discharge <br />rate during the 25-year storm increases less than 2 cfs; therefore, the <br />overall impact of this ditch is insignificant. <br />The diversion ditch was designed using the following input data: <br />Watershed Area = 42.9 ac. <br />CN = 91.0 <br />P10 = 1.6 inches <br />tc = 0.068 hrs. <br />Slope = 1.0% <br />n = 0.025 <br />z = 2:1 (v-ditch) <br />Output Data: <br />Q10 = 36.5 cfs <br />do = 1.9 ft. <br />Froude No.= 0.96 <br />Total Depth = 3.0 ft. <br />In conclusion, the diversion ditch will be utilized for only a short <br />time until Pond 009 is constructed. Pond 008's design is conservative <br />at this time because the 008 design assumed a worst case condition when <br />all runoff will drain into Pond 008. Adding the acreage to Pond 008's <br />• watershed and rerunning SEDIMOT II for each storm event shows <br />insignificant impacts on Pond 008. Exhibit 7-7 has been revised to <br />include the 008 Diversion Ditch watershed. <br />