Laserfiche WebLink
;t <br />_~e 3 <br />,:Jm Herron <br />Fi1I Site Foundational Geohydrology <br />The second paragraph of section 13.2.2, found on page 13-4, states that <br />"the water table was found to be well below the ground surface throughout_ _ <br />the disposal area." Table 13.2.1 (page I3-5), however, indicates that on <br />May 17, 1980 water levels in wells no. 2 and 3 were +0.5 feet and 1.2 feet <br />below ground surface, respectively. The application does rrot contaia <br />sufficient justification to support the applicant's contention, as stated <br />on page 13-7, that "proposed drainage improvements are expected to maintain <br />the water level in this area, at least 5 feet below existing grouad- <br />surface". <br />Section 30 CFR 817.71(1) requires the constriction of a durable rock <br />underdrain system to prevent infiltration of groundwater into the <br />spoil material. The application should be amended to iaclude an approp- <br />riately designed underdrain system within the toe area of the fiZ2 adjoining <br />the highwater areas near test wells 2 and 3. <br />Slope Stability Analysis <br />Slope stability analyses are only significant if they appropriately model <br />the material, mechanical and hydrogeological properties of the refuse . <br />disposal fill proposed. This application states, on page 13-I6, "the <br />long term stability of the pile has been analyzed based on the assumption <br />of 85~ of maximum density and the prescribed factor of safety (30 6FR 817.71) <br />may not be achieved without this density. <br />The stability analysis completed by Espey, Huston and Associates, Snc., <br />employed the SSSAB I slope stability computer program developed by Dx. <br />-= Stephen G. Wright, University of Texas at Austin., This computer program <br />_. - utilizes the spencer method of slices and as such, is a recognized and <br />acceptable method of slope stability analysis. The cross sections analyzed <br />for both phase I of the fill and the complete proposed fill, appear <br />representative and are therefore appropriate. With the appropriate under- <br />drain modifications mentioned above, the potentiometric surfaces assumed <br />in the computer analysis would be acceptable. <br />The material parameters utilized in the stability analysis do not appear <br />to be representative of the refuse fill being proposed_ The application <br />(page 13-8) utilizes material strength parameters determined by "others". <br />The application should contain the reference test results and discussions <br />of their various determination. The application also contains compaction <br />testing results for the existing colluvial soils and representative waste <br />material, depicted in figure 13.3.1. The waste zock maximum density was <br />determined to be 100pcf (pounds per cubic foot) at approximately IS$ moisture <br />content and the colluvial soils maximum density was determined to be 98pcf, <br />at approximately 20~ moisture content. However, the stability analysis <br />(tort' d) <br />