Laserfiche WebLink
III. COMMENTS -COMPLIANCE <br />Below are comments on the inspection. The comments include discussion of observations made <br />during the inspection. Comments also describe any enforcement actions taken during the <br />inspection and the facts or evidence supporting the enforcement action. <br />Well 96 <br />First sample Second Sample <br />Temp.- 12.1 degrees C 7.6 degrees C <br />pH- 8.34 7.8 <br />Ec- 2080 2190 <br />Well FPW <br />First sample Second sample <br />Temp.- 10.7 11 <br />pH- 7.14 7.07 <br />Ec- 790 946 <br />Well AMW-1 <br />First sample Second sample <br />Temp.- 9.5 10.1 <br />pH- 7.10 7.05 <br />Ec- 1356 1344 <br />Well SMW-2 <br />First sample Second sample <br />Temp.- 8.7 12.1 <br />pH- 7.10 6.65 <br />Ec- 9970 9210 <br />Both readings from the FPW and AMW-1 were taken by the operator <br />using his Ec meter. All other readings were taken using one of <br />pMG's Ec meters. There were some differences in the readings <br />between the first and second sample and in between the different <br />meters. <br />