Laserfiche WebLink
III. COMMENTS -COMPLIANCE <br />Below are comments on the inspection. The comments include discussion of observations made <br />during the inspection. Comments also describe any enforcement actions taken during the inspection <br />and the facts or evidence supporting the enforcement action. <br />The spring discharge was analyzed in the field for temperature, pH, and conductivity. The <br />ph/conductivity meter was calibrated in the field immediately prior to taking the field <br />measurements. Measurements were made at two locations: 1) from the discharge at the end of <br />the pipe, and 2) from the immediate area of discharge neaz the east side of the slide mass, before <br />the spring flow enters the pipe. The results of these measurements aze listed below: <br />End of Pipe Discharge -Flow= 37.5 gallons per minute, Temperature= 86 degrees Fahrenheit, <br />pH= 6.96, Conductivity= 5,080 micromhos <br />Discharge Directly from Spring -Flow not measured, Temperature=87 degrees Fahrenheit, <br />pH=6.45, Conductivity= 5,190 micromhos <br />Su~oort Facilities <br />As part of the ongoing reclamation effort, please continue to remove the trash and debris that has <br />accumulated east of the former shop building. <br />Reclamation Success <br />The Bear No. 1 and Beaz No. 2 reclaimed areas were inspected as part of this complete <br />inspection. Both reclaimed areas were free of snow cover and appeaz to be stable. <br />