My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSPEC18366
DRMS
>
Back File Migration
>
Inspection
>
INSPEC18366
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 9:19:44 PM
Creation date
11/18/2007 9:25:14 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1994117
IBM Index Class Name
Inspection
Doc Name
MINERALS PROGRAM INSPECTION REPORT
Inspection Date
3/31/1998
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- • (Page 2) <br />MINE ID # OR PROSPECTING ID # M-9d-117 <br />INSPECTION DATE 3-31-98 <br />OBSERVATIONS <br /> <br />INSPECTOR'S INITIALS GC <br />This inspection was conducted to determine the water levels within the Hazel A adit and the tailings <br />pond axxd determine the condition of the closed circuit pump back system. There was no operator's <br />representative on site. Ernie Simmons of ITEC Mineral, Inc. and Bruce Bivert were present on-site. <br />There was a cover of 6" to 12• of snow with drifts up to 2.' <br />SAZBL-7\ AdiG <br />The Ha::el-A adit was inspected. Water was seeping from the ceiling along the visible length of the <br />adit. There was no freeboard behind the bulkhead and, because the pump behind the bulkhead was not <br />operational, water was overtopping the structure and passing through leaks between the bulkhead and <br />the rib at an estimated rate of one to two gallons per minute. The overflow water had pooled behind <br />the secondary, or coffer, dam where it was being pumped up to the tailings dam. This is not the <br />approv=_d use of the coffer dam and pump and it is anticipated that continued pumping will result in <br />pump failure and ultimately discharge of water from the Hazel-A portal. It also appears that the <br />coffer dam pump will not be able to keep up with any significant increase of inflow into the adit. <br />(See F~roblem PB-1) The approved permit requires that the water be pumped from behind the bulkhead <br />through a pvc line to the surge tanks in the mill. To maintain a zero discharge facility, the water <br />in the surge tanks is run into the tailings pond where it is evaporated. <br />The entire pump back system appears to be in disrepair. The line running to the surge tanks in the <br />mill appears to be broken and needs to be repaired. The surge tank piping apparently was not drained <br />over the winter and some of the piping has apparently been damaged by ice. The decant line between <br />the Hazel A adit and the tailings pond is open to facilitate pumping of Hazel-A adit water to the <br />tailings pond. The operator is required to keep this line closed. The operator is also required <br />to keep the water behind the bulkhead as low as possible at all times. At no time is the freeboard <br />allowed to be less than 12 inches. The present condition of the pump back system is unacceptable. <br />The operator will be required to submit a plan to prevent water from discharging from the Hazel A adit <br />no later than April 16, 1998 and implement it. The approved system must be repaired and operating <br />no later than April 22, 1998. (See Problem PB-2i. After that date, any freeboard of less than 12 <br />inches behind the Hazel A bulkhead may be considered a possible violation to the Gold Hill Mill <br />permit. <br />The H+izel-A log book was inspected and was found to be up to date through 3/30/98, however, the detail <br />was not as required in the permit. In the future, all required information must be entered to avoid <br />problems or possible violations. <br />Tailings Poad <br />There was approximately 18" of freeboard in the tailings pond. The spray evaporative system was <br />not operating. The sprinkler system was in place on the uphill side of the pond and on the downhill <br />side was partially covered with snow. Effective immediately, this system must be functional and <br />operating. During future inspections, failure to have the evaporative system operating properly may <br />result in a possible violation to the Gold Hill Mill permit. <br />Use of the designation letter 'Y" (Y=Inspected and Found in Compliance) in the GENERAL INSPECTION <br />TOPIC`S section of page 1 of this report is not intended to abrogate pending problems and possible <br />violations identified in previous reports filed for this site. Use of the letter designation 'Y^ in <br />this report is intended to indicate that no new problems or possible violations were identified. <br />
The URL can be used to link to this page
Your browser does not support the video tag.