My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2025-10-20_REVISION - M1980244 (9)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2025-10-20_REVISION - M1980244 (9)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2025 10:22:10 PM
Creation date
10/21/2025 10:06:45 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
10/20/2025
Doc Name Note
4. TABLES
Doc Name
Request for Technical Revision
From
CC&V
To
DRMS
Type & Sequence
TR153
Email Name
ERR
ZTT
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2Cripple Creek & Victor Gold Mining CompanyValley Leach Facility 2 Phase 3Stage B.1 Record of ConstructionEarthworks Testing Summary and FrequencyStructural Fill (SF)Soil Liner Fill (SLF)Drain Cover Fill (DCFO)Quantity of Material Placed (cy) 2,450 43,944 87,890Particle Size Tests Performed 1 14 11Specified Particle Size Test Frequency 50,000 4,000 20,000Actual Particle Size Test Frequency 2,450 3,139 7,990Atterberg Limit Tests Performed 1 14 11Specified Atterberg Limit Test Frequency 50,000 4,000 20,000Actual Atterberg Limit Test Frequency 2,450 368 7,990Laboratory Compaction Tests Performed See Note 1 14 N/ASpecified Compaction Test Frequency N/A 4,000Actual Compaction Test Frequency N/A 3,139Permeability Tests Performed N/A 14 N/ASpecified Permeability Test Frequency 4,000Actual Permeability Test Frequency 3,139Moisture Content Tests Performed See Note 1 102 N/ASpecified Moisture Content Test Frequency 2,000 500Actual Moisture Content Test Frequency See Note 1 431Field Nuclear Density Tests Performed See Note 1 102 N/ASpecified Nuclear Density Test Frequency 2,000 500Actual Nuclear Density Test Frequency See Note 1 431Field Depth Verification Tests Performed N/A 102 N/ASpecified Depth Verification Test Frequency 2.0 test/acActual Depth Verification Test Frequency 4Notes:2. All frequencies are based on quantities in cubic yards unless stated otherwise.3. N/A = Not ApplicableMaterial QuantityNumber of TestsTest FrequencyN/AN/A1. The method of compaction technique was used in accordance with the project technical specifications due to the large particle size.N/AN/AN/AN/AN/APage 1 of 1
The URL can be used to link to this page
Your browser does not support the video tag.