Laserfiche WebLink
A CZ Laboratories, Inc. a • 0 . 11s , • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 ' - • • <br /> Ouray Silver Mines ACZ Project ID: L71828 <br /> r r rD QUAL DESCRIPTION <br /> L71828-01 NG538856 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG538066 Cyanide,total M335.4-Colorimetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> WG538959 Nitrate/Nitrite as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG538176 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG537858 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540C Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG537892 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG538421 Sulfate D516-02/-07/-11- M1 Matrix spike recovery was high,the recovery of the <br /> TURBIDIMETRIC associated control sample(LCS or LFB)was acceptable. <br /> L71828-02 VVG538856 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG538066 Cyanide,total M335.4-Colorimetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> WG538959 Nitrate/Nitrite as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG538176 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG537858 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG537892 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG538421 Sulfate D516-02/-071-11- M1 Matrix spike recovery was high,the recovery of the <br /> TURBIDIMETRIC associated control sample(LCS or LFB)was acceptable. <br /> L71828-03 NG538856 Chloride SM4500CI-E RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG538066 Cyanide,total M335.4-Colorimetric w/ M2 Matrix spike recovery was low,the recovery of the <br /> distillation associated control sample(LCS or LFB)was acceptable. <br /> WG538959 Nitrate/Nitrite as N M353.2-H2SO4 preserved RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG538176 Phosphorus,total M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG537858 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG537892 Residue,Non-Filterable(TSS)@105C SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> SM2540D Z3 Sample volume yielded a residue less than 2.5 mg <br /> WG538421 Sulfate D516-02/-07/-11- M1 Matrix spike recovery was high,the recovery of the <br /> TURBIDIMETRIC associated control sample(LCS or LFB)was acceptable. <br /> REPAD.15.06.05.01 <br /> L71828-2203281147 Page 21 of 26 <br />