My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-06-24_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-06-24_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 1:16:54 PM
Creation date
6/24/2021 12:14:09 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
6/24/2021
Doc Name
Adequacy Review Response #3
From
Ouray Silver Mines, Inc.
To
DRMS
Type & Sequence
TR14
Email Name
LJW
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ASME B31.3-2016 <br /> (b) In addition to the procedure for making the bonds, (a) Test Assembly. The assembly shall be fabricated in <br /> the BPS shall specify at least the following: one pipe size in accordance with the BPS and shall con- <br /> (1) all materials and supplies (including storage tain at least one of each different type of joint identified <br /> requirements) in the BPS.More than one test assembly may be prepared <br /> (2) tools and fixtures (including proper care and if necessary to accommodate all of the joint types or to <br /> handling) assure that at least one of each joint type is loaded in <br /> (3) environmental requirements (e.g.,temperature, both circumferential and longitudinal directions. The <br /> humidity, and methods of measurement) size of pipe and fittings in the assembly shall be as <br /> (4) joint preparation follows: <br /> (5) dimensional requirements and tolerances (1) When the largest size to be qualified is DN 100 <br /> (6) cure time (NPS 4)or smaller,the test assembly shall be the largest <br /> (7) protection of work size qualified. <br /> (8) tests and examinations other than those (2) When the largest size to be qualified is greater <br /> required by para. A328.2.5 than DN 100 (NPS 4),the size of the test assembly shall <br /> (9) acceptance criteria for the completed test be between 25% and 100% of the largest piping size <br /> assembly qualified,but shall be a minimum of DN 100 (NPS 4). <br /> (b) Burst Test Method. The test assembly shall be sub- <br /> A328.2.2 Procedure Qualification by Others. Subject jected to a burst test in accordance with the applicable <br /> to the specific approval of the Inspector,a BPS qualified sections of ASTM D1599 5 The time to burst in this stan- <br /> by others may be used provided that dard may be extended. The test is successful if failure <br /> (a) the Inspector satisfies him/herself that the initiates outside of any bonded joint. <br /> proposed qualified BPS has been prepared and executed (c) Hydrostatic Test Method. The test assembly shall be <br /> by a responsible recognized organization with expertise subjected to hydrostatic pressure of at least PT for not <br /> in the field of bonding less than 1 hr with no leakage or separation of joints. <br /> (b) by signature, the employer accepts both the BPS (1) For thermoplastics, PT shall be determined in <br /> and procedure qualification record (PQR) as his own accordance with eq. (27) <br /> (c) the employer has at least one currently employed <br /> bonder who, while in his employ, has satisfactorily PT = o.8oT�SS+SH) 27 <br /> passed a performance qualification test using the pro- D -T <br /> posed qualified BPS <br /> where <br /> A328.2.3 Performance Qualification by Others. D = outside diameter of pipe <br /> Without the Inspector's specific approval, an employer SH = mean long term hydrostatic strength (LTHS) <br /> shall not accept a performance qualification test made in accordance with ASTM D2837.Use twice the <br /> by a bonder or bonding operator for another employer. 23°C(73°F)HDB design stress from Table B-1 if <br /> If approval is given,it is limited to work on piping using listed, or use manufacturer's data. <br /> the same or equivalent BPS.An employer accepting such Ss = mean short term burst stress in accordance <br /> performance qualification tests shall obtain a copy of the with ASTM D1599,5 from Table B-1 if listed, <br /> performance qualification test record from the previous _ otherwise from manufacturer's data <br /> employer showing the name of the employer by whom T = nominal thickness of pipe <br /> the bonder or bonding operator was qualified,the date <br /> of such qualification,and the date the bonder or bonding (2) For RTR (laminated and filament-wound) and <br /> operator last bonded pressure piping under such per- RPM,PT shall be three times the manufacturer's allow- <br /> formance qualification. able pressure for the components being joined. <br /> A328.2.4 Qualification Records. The employer shall (3) The test shall be conducted so that the joint <br /> maintain a self-certified record, available to the owner is loaded in both the circumferential and longitudinal <br /> or owner's agent and to the Inspector, of the BPS used directions. <br /> and the bonders or bonding operators employed by A328.2.6 Performance Requalification. Renewal of <br /> him/her,and showing the dates and results of BPS quali- a bonding performance qualification is required when <br /> fications and bonding performance qualifications. <br /> A328.2.5 Qualification Tests. Tests, as specified in 5 Titles of referenced standards and specifications are listed in <br /> para. A328.2.1(a), shall be performed to qualify each Table A326.1,except ASTM D1599,Test Method for Resistance to <br /> BPS and the performance of each bonder and bonding Short-Time Hydraulic Pressure of Plastic Pipe,Tubing,and Fittings; <br /> operator.Test assemblies shall conform to(a)below and ASTM D2657,Practice for Heat Fusion Joining of Polyolefin Pipe <br /> and Fittings;ASTM D2855,Practice for Making Solvent-Cemented <br /> the test method shall be in accordance with either (b) Joints with PVC Pipe and Fittings;and ASTM F1290,Practice for <br /> or (c). Electrofusion Joining Polyolefin Pipe and Fittings. <br />
The URL can be used to link to this page
Your browser does not support the video tag.