Laserfiche WebLink
A CIZ <br /> Laboratories, Inc. • • • • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 • • <br /> ACZ Project ID: L65443 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 1,2,4-Trimethylbenzene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> 1,2-Dibromo-3-chloropropane M826OC/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,2-Dibromoethane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,2-Dichlorobenzene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,2-Dichloroethane M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M826OC/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> M8260C/D GC/MS VC CCV recovery was above the acceptance limits.Target <br /> analyte was not detected in the sample[<MDL]. <br /> 1,2-Dichloropropane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,3,5-Trimethylbenzene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,3-Dichlorobenzene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,3-Dichloropropane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,4-Dichlorobenzene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 2,2-Dichloropropane M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 2-Butanone M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> M8260C/D GC/MS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> 2-Chlorotoluene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 2-Hexanone M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GCIMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1Ox MDL). <br /> M8260C/D GUMS VC CCV recovery was above the acceptance limits.Target <br /> analyte was not detected in the sample[<MDL]. <br /> 4-Chlorotoluene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 4-Isopropyltoluene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 4-Methyl-2-Pentanone M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> M8260C/D GC/MS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> REPAD.15.06.05.01 <br /> L65443-2105101543 Page 30 of 37 <br />