Laserfiche WebLink
ACZ Laboratories, Inc. • • - - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 01 - • • <br /> ACZ Project ID: L65443 <br /> METHODACZ ID WORKNUM PARAMETER QUAL DESCRIPTION <br /> analyte was not detected in the sample[<MDL]. <br /> 4-Chlorotoluene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 4-Isopropyltoluene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 4-Methyl-2-Pentanone M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> M8260C/D GC/MS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> Acetone M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> M8260C/D GC/MS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> Acrylonitrile M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> M8260C/D GC/MS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> Benzene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Bromobenzene M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Bromochlorom ethane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> M8260C/D GUMS VB CCV recovery was outside of acceptance limits.See Case <br /> Narrative. <br /> Bromodichloromethane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Bromoform M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Bromomethane M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Carbon Disulfide M8260C/D GUMS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Carbon Tetrachloride M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Chlorobenzene M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Chloroethane M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Chloroform M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Chloromethane M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> REPAD.15.06.05.01 <br /> L65443-2105101543 Page 27 of 37 <br />