Laserfiche WebLink
A40Z Laboratories, Inc. • • • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 w - • • <br /> ACZ Project ID: L65443 <br /> ACZ ID WORKNUM PARAMETER .. QUAL DESCRIPTION <br /> L65443-01 WG518736 2,4-Dimethylphenol M8270D/E GUMS R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> 2-Nitroaniline M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> 3,3-Dichlorobenzidine M8270D/E GC/MS N1 See Case Narrative. <br /> 4-Chloroaniline M8270D/E GC/MS R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> 4-Nitroaniline M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Aniline M8270D/E GUMS VC CCV recovery was above the acceptance limits.Target <br /> analyte was not detected in the sample[<MDL]. <br /> Benzidine M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzo(a)anthracene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzo(a)pyrene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzo(b)fluoranthene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzo(g,h,i)perylene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzo(k)fluoranthene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Benzoic Acid M8270D/E GUMS R1 RPD exceeded the method or laboratory acceptance limit. <br /> See Case Narrative. <br /> Bis(2-ethylhexyl)phthalate M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Chrysene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Dibenzo(a,h)anthracene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Di-n-octyl phthalate M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Indeno(1,2,3-cd)pyrene M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> Nitrobenzene M8270D/E GUMS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> N-Nitrosodiphenylamine M8270D/E GUMS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> L65443-02 WG517626 1,1,1,2-Tetrachloroethane M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,1.1-Trichloroethane M8260C/D GUMS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,1,2,2-Tetrachloroethane M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,1,2-Trichloroethane M826OC/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,1-Dichloroethane M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GC/MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> 1,1-Dichloroethene M8260C/D GUMS M1 Matrix spike recovery was high,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M8260C/D GUMS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> 1,1-Dichloropropene M8260C/D GC/MS M1 Matrix spike recovery was high,the recovery of the <br /> REPAD.15.06.05.01 <br /> L65443-2105101543 Page 25 of 37 <br />