Laserfiche WebLink
Fill Testing Client: Project: <br /> 0 AGW <br /> Report#:FT-000002 Alexco Water and Environmental 201007 <br /> Report Date:10/23/2020 131 East Lincoln Avenue TR-28 North Waste <br /> Field Services Test Method:ASTM D 6938 Suite 200 Rock Pile Diversion Channel(Schwartzwalder <br /> 2180 South Ivanhoe Street,Suite 5 Fort Collins,CO 80524 M,,, <br /> Denver,CO80222 Golden,CO <br /> Phone:t303)759-8100 <br /> Test Results <br /> In Place In Place Optimum <br /> Optimum Maximum In Place Dry Wet Probe Moisture <br /> Retest Test Soil Moisture Dry Density Moisture Density Density Depth Percent Min Comp. Tolerance <br /> Test# Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (pcf) (in) Compaction (%) (%) Remark <br /> 14 9/24/20 02 ASTM A-1-1b 5.7 144.3 6.1 136.9 145.2 8 95 95 -3/3 Pass <br /> D1557 <br /> 15 9/24/20 02 ASTM A-1-1b 5.7 144.3 7.0 136.4 146.0 8 95 95 -3/3 Pass <br /> D1557 <br /> 16 9/24/20 02 ASTM A-1-b 5.7 144.3 6.9 137.0 146.4 8 95 95 -3/3 Pass <br /> D1557 <br /> 17 9/24/20 02 ASTM A-1-b 5.7 144.3 7.9 137.8 148.7 8 95 95 -3/3 Pass <br /> D1557 <br /> 18 9/24/20 02 ASTM A-1-b 5.7 144.3 12.1 116.9 131.1 8 81 95 -3/3 Fail <br /> D1557 <br /> 19 18 9/24/20 02 ASTM A-1-b 5.7 144.3 5.8 137.4 145.4 8 95 95 -3/3 Pass <br /> D1557 <br /> 9/24/20 02 ASTM A-1-b 5.7 144.3 6.3 1 136.5 145.1 1 8 95 95 -3/3 Pass <br /> D1557 <br /> Test Information <br /> Gauge <br /> Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician <br /> 14 Trickle Channel:Diversion Channel,Station:0+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 15 Trickle Channel:Diversion Channel,Station:1+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 16 Trickle Channel:Diversion Channel,Station:2+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 17 Trickle Channel:Diversion Channel,Station:3+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 18 Trickle Channel:Diversion Channel,Station:4+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 19 Trickle Channel:Diversion Channel,Station:4+75 2.0 AEG Troxler/3430/38192/ Platzer,Neal <br /> 20 Trickle Channel:Diversion Channel,Station:5+75 1 2.0 JAEG Troxler/3430/38192/ Platzer,Neal <br /> Remarks Comments <br /> Pass:Density Pass/Moisture Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as <br /> "Backscatter".Gauge calibration data on file with the testing agency. <br /> Fail:Density Fail/Moisture Fail 20:TThe Contractor,ENSERO utilized a loader,excavator,and <br /> sheepsfoot compactor to place,process and apply compactive effort <br /> to the subgade.Moisture was added with a water truck. <br /> AEG=Above Existina Grade <br /> A representative of the Contractor was informed of our test results and observations.Observation services were conducted on an on-call basis.The test Page 1 of 1 <br /> depths and locations are approximate and are based upon information provided by the Contractor.The lateral and vertical extents of any subexcavation were <br /> not measured or verified by this firm.The site conditions noted and test results reported apply only to the locations and depths tested at the time of our visit. <br /> It remains the Contractor's responsibility to apply the necessary compactive effort and moisture conditioning to meet the project specifications. <br />