Laserfiche WebLink
EARTHWORK SPECIFICATIONS: <br /> 1. ELEVATIONS AND ROAD WIDTHS ARE BASED ON LIMITED SURVEY DATA AND MAY NOT REFLECT ACTUAL CONDITIONS IN THE FIELD AT ALL LOCATIONS. <br /> 2. WET SUBGRADE SURFACES IMMEDIATELY PRIOR TO FILL OR ROADBASE PLACEMENT.THE SUBGRADE SHALL BE PROOF-ROLLED WITH A MINIMUM OF TWO(2) <br /> COVERAGES OF APPROVED COMPACTION EQUIPMENT. <br /> 3. PRIOR TO PLACING STRUCTURAL BACKFILL ON ROAD SURFACES,SCARIFY THE TOP SIX(6)INCHES OF SUBGRADE MATERIAL. <br /> 4. SELECT EMBANKMENT FILL SHALL BE A MIXTURE OF FINES,SAND,AND GRAVEL WITH A MAXIMUM PARTICLE SIZE OF SIX(6)INCHES,A MIN.OF 50%PASSING THE <br /> NO.4 SIEVE,A MIN.OF 15%PASSING THE NO.200 SIEVE, AND SHALL BE GENERALLY FREE OF PEAT,TWIGS,GRASS, OR LESS THAN THREE(3%)ORGANIC <br /> MATERIAL BY WEIGHT.SELECT EMBANKMENT FILL SHALL BE FREE OF DELETERIOUS MATERIALS,DEBRIS,AND TRASH.SELECT EMBANKMENT FILL FILL SHALL BE <br /> FURNISHED FROM ON-SITE EXCAVATED MATERIALS. BORROW SOURCES FOR SELECT EMBANKMENT FILL SHALL BE AS SHOWN ON THE DRAWINGS OR APPROVED <br /> BY THE ENGINEERING DEPARTMENT. <br /> 4. EMBANKMENT FILL SHALL BE A MIXTURE OF FINES,SAND,AND GRAVEL WITH A MAXIMUM PARTICLE SIZE OF SIX(6)INCHES, AND SHALL BE GENERALLY FREE OF <br /> PEAT,TWIGS,GRASS, OR LESS THAN THREE(3%)ORGANIC MATERIAL BY WEIGHT.SELECT EMBANKMENT FILL SHALL BE FREE OF DELETERIOUS MATERIALS, <br /> DEBRIS,AND TRASH.SELECT EMBANKMENT FILL FILL SHALL BE FURNISHED FROM OWSITE EXCAVATED MATERIALS. BORROW SOURCES FOR SELECT ESTIMATED BILL OF MATERIALS <br /> EMBANKMENT FILL SHALL BE AS SHOWN ON THE DRAWINGS OR APPROVED BY THE ENGINEERING DEPARTMENT. <br /> 5. SELECT EMBANKMENT FILL AND EMBANKMENT FILL SHALL BE PLACED IN HORIZONTAL LIFTS NOT EXCEEDING A THICKNESS OF EIGHT(8)INCHES BEFORE <br /> COMPACTION.STRUCTURAL FILL SHALL BE COMPACTED TO A MINIMUM OF NINETY-FIVE PERCENT(95%)OF THE MODIFIED PROCTOR DRY DENSITY IN MATERIAL UNIT OF MEASURE QTY. <br /> ACCORDANCE WITH ASTM D1557. IN-PLACE MOISTURE CONTENT OF STRUCTURAL FILL SHALL BE WITHIN TWO PERCENT(2%)OF THE OPTIMUM MOISTURE <br /> CONTENT AS DETERMINED BY ASTM D1557. SELECT EMBANKMENT FILL VOLUME(COMPACTED CY) 2360 <br /> 6. IN-PLACE DENSITY AND MOISTURE TESTS SHALL BE PERFORMED BY AN OWNERS REPRESENTATIVE FOR EVERY 500 CY OF STRUCTURAL FILL OR ONE TEST PER <br /> LIFT,WHICHEVER IS MORE FREQUENT.GRADATION ANALYSES FOR IMPORTED MATERIAL SHALL BE SUBMITTED TO THE ENGINEER FOR EVERY 500 CY OF EMBANKMENT FILL VOLUME(COMPACTED CY) 13250 <br /> STRUCTURAL FILL. <br /> 7. AN APPROVED METHOD SPECIFICATION FOR COMPACTION MAY BE USED IN LIEU OF IN-PLACE DENSITY TESTS. THE METHOD SPECIFICATION WILL BE DEVELOPED ROAD BASE(COURSE) VOLUME(COMPACTED CY) 1980 <br /> BY THE ENGINEER AND BASED ON THE ACTUAL COMPACTION EQUIPMENT TO BE USED BY THE CONTRACTOR. THE ENGINEER RESERVES THE RIGHT TO PERFORM <br /> ADDITIONAL DENSITY TESTING AT ANY TIME TO VALIDATE THE USE AND EFFECTIVENESS OF THE APPROVED METHOD SPECIFICATION. 12 SF CONCRETE BLOCKS COUNT 12 <br /> 8. ROAD BASE(COURSE)SHALL CONFORM TO STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION,COLORADO DEPARTMENT OF TRANSPORTATION, 42"DIA.DR 17 HOPE PIPE LENGTH(FEET) 25 <br /> 2011(OR LATEST EDITION),SECTION 703.03: AGGREGATES FOR BASES,CLASS 5 AGGREGATE BASE COURSE,AND SHALL CONSIST OF THE FOLLOWING GRADING <br /> REQUIREMENTS: CONCRETE VOLUME(CY) 6 <br /> SIEVE SIZE PERCENT PASSING(BY WEIGHT) -"CRUSHED ROCK VOLUME(CY) 30 <br /> 1}INCH 100 *TABLE NOT UPDATED WITH AS-BUILT QUANTITIES <br /> 1 INCH 95-100 <br /> NO.4(4.75 MM) 30-70 <br /> NO.200(0.075 MM) 3-15 <br /> 8. ROAD BASE(COURSE)SHALL BE SPREAD IN SUCH A MANNER AS TO ENSURE A SMOOTH,UNIFORM LAYER AND TO AVOID SEGREGATION.BASE COURSE SHALL BE <br /> PLACED IN SIX(6)INCH THICK LOOSE LIFTS AND COMPACTED WITH A MINIMUM OF FOUR(4)COVERAGES OF AN APPROVED VIBRATORY SMOOTH-DRUM <br /> COMPACTOR. THERE ARE NO COMPACTION OR MOISTURE DENSITY REQUIREMENTS FOR THE BASE COURSE. <br /> 9. REMOVE CONCRETE JERSEY BARRIERS FOR CONSTRUCTION OF RAISE.PLACE ON ROAD SURFACE UPON COMPLETION.REPLACE BARRIERS AS NEEDED.CONCRETE <br /> BARRIERS SHALL BE PRECAST TYPE 7. <br /> 10. BLUE STAKE PERMITS MUST BE ACQUIRED PER HENDERSON MILL POLICIES PRIOR TO BEGINNING OF WORK. <br /> 11. CLEARING OF VEGETATION AND TOPSOIL STRIPPING TO A MIN.DEPTH OF 6 INCHES(6")SHALL OCCUR,WHERE APPLICABLE,PRIOR TO PLACEMENT OF FILL AND <br /> BEFORE DEVELOPMENT OF FILL FROM BORROW AREAS.ADJUST STRIPPING DEPTH IF REQUIRED TO REMOVE ALL TOPSOIL.UPON COMPLETION OF THE FILL <br /> PLACEMENT,SPREAD TOPSOIL EVENLY ON SLOPES AND RESEED. <br /> PRECAST MODULAR BLOCK SPECIFICATION: <br /> 1. BLOCKS SHALL BE 12 SF,NOMINAL 2 FOOT HIGH x 6 FOOT LONG x 2 FOOT DEEP. <br /> 2. DIMENSION TOLERANCE SHALL BE+/-j INCH FOR HEIGHT,+/-} FOR LENGTH AND+/-1 INCH FOR WIDTH. <br /> 3. CONCRETE FOR BLOCKS SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI. ENTRAINED AIR CONTENT SHALL BE BETWEEN 5 AND 7%. <br /> 4. REINFORCING SHALL HAVE A MINIMUM YIELD STRENGTH OF 60 KSI. MINIMUM CLEAR COVER TO REINFORCEMENT SHALL BE 1}INCHES. <br /> 5. BLOCK SUPPLIED BY PEAK MATERIALS. <br /> d <br /> E <br /> U <br /> s <br /> s <br /> s <br /> Y <br /> a <br /> 'This droWing together With any and oil odditfons, w Climax Molybdenum Henderson Mill <br /> ® �a any aM Sox oESlan �a correctlms, changes and alterations thereof is the Climax Molybdenum SEEPWATER DETENTION BERM Parshall,CO <br /> Z ® mne Tan eo+v oeslos rnenee property of Climax Molybdenum Company and is p • s <br /> o EM IasUEoFOacON9TaUC ON furnished on the express condition that 1t shall w A Freeport-McMoRan Company ROAD RAISE 03/18 <br /> N 5A1M not he reproduced, copied,lent, or disposed of Z TEM 1333.01.13 <br /> 0 TEN aEcoao onnwlno directly or indirectly,nor used for any other w 3700 S.IN II STREET DRAWING NO. <br /> _ 0 purpose than far which it is speciflcolly furnished w W.W.WHEEL SPECIFICATIONS AND MATERIALS 03118ER EN—EW000,COCa 9C11 a-a SMM <br /> aer sea rces n nears sCCEF1a)er <br /> Q Without the prior Written consent of 90id Climax W 6 AS CICIATE6, INC 303-711-11 <br /> �JVoljbdenum Campany.� a vnx 3C3-7613❑ C6 <br />