Laserfiche WebLink
All of the QC samples met the required acceptance limits. <br /> Technical Information: <br /> Holding Time <br /> All sample procedures for this sample set were performed within the required holding time. <br /> Sample Re-prep/Re-analysis <br /> None of the samples in this sample set required reprep or reanalysis. <br /> Chemical Recoveries <br /> All chemical recoveries meet the required acceptance limits for this sample set. <br /> Recounts <br /> None of the samples in this batch were recounted. <br /> Miscellaneous Information: <br /> Data Exception(DER)Documentation <br /> Data exception reports are generated to document any procedural anomalies that may deviate from referenced <br /> SOP or contractual documents.A data exception report(DER)was not generated for this SDG. <br /> Sample-Specific MDA/MDC <br /> The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC. <br /> Additional Comments <br /> The matrix spike, 1203053776(Sunday MW 3),aliquot was reduced to conserve sample volume. <br /> Oualifier Information <br /> Manual qualifiers were not required. <br /> Method/Analysis Information <br /> Product: Gross Alpha/Beta in Drinking Water EPA 900.0 <br /> Analytical Method: EPA 900.0 <br /> Analytical Batch Number: 1375019 <br /> Sample ID Client ID <br /> 344616001 Sunday MW 1 <br /> 344616002 Sunday MW I <br /> 344616003 Sunday MW 2 <br /> 344616004 Sunday MW 3 <br /> 1203055933 Method Blank(MB) <br /> 1203055934 344616002(Sunday MW 1D)Sample Duplicate(DUP) <br /> 1203055935 344616002(Sunday MW 1D)Matrix Spike(MS) <br /> 1203055936 344616002(Sunday MW 1D)Matrix Spike Duplicate(MSD) <br /> 1203055937 Laboratory Control Sample(LCS) <br /> Page 78 of 94 <br />