My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-12-13_REVISION - M1980244 (66)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2019-12-13_REVISION - M1980244 (66)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2025 2:43:32 AM
Creation date
12/17/2019 8:39:27 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
12/13/2019
Doc Name Note
Appendix 11 -12
Doc Name
Request For Amendment To Permit
From
CC&V
To
DRMS
Type & Sequence
AM13
Email Name
TC1
MAC
BFB
ERR
JPL
AWA
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M CG&V MINING <br /> NEW TRUCK SHOP ANTIFREEZE PREMIX <br /> ACUREN FORMAL EXTERNAL INSPECTION 6-2011 <br /> Item Status Comments <br /> 1.0 Tank Containment <br /> 1.1 Containment structure in SMALL CRACKS EXIST IN CONCRETE. <br /> satisfactory condition? ❑ Yes ❑X No* <br /> 1.2 Drainage pipes/valves fit for <br /> continued service ❑Yes ❑ No* X N/A TANK IS INSIDE OF BUILDING. <br /> 2.0 Tank Foundation and Supparts <br /> 2.1 Evidence of tank settlement <br /> or foundation washout? ❑Yes ❑X No* <br /> 2.2 Cracking or spalling of <br /> concrete pad or ring wall? ❑ X Yes ❑ No* N/A SMALL CRACKS EXIST. <br /> 2.3 Tank supports in satisfactory <br /> condition? ❑X Yes ❑No* N/A <br /> 2.4 Water able to drain away from <br /> tank? ❑ X Yes ❑ No* <br /> 2.5 Grounding strap secured and <br /> in 000d condition? ❑Yes ❑ No* X N/A <br /> 3.0 Cathodic Protection <br /> 3.1 CP system functional? ❑Yes ❑ No* X VA <br /> 3.2 Rectifier Reading: ❑Yes ❑ No* X WA <br /> 4.0 Tank External Coating <br /> 4.1 Evidence of paint failure? u Yes u X No* <br /> 5.0 Tank Shell/Heads <br /> 5.1 Noticeable shell/head <br /> distortions, buckling,denting or ❑ Yes ❑X No* <br /> 5.2 Evidence of shellfhead <br /> corrosion or cracking? uYes ❑ X No* <br /> 6.0 Tank Manwa s PiRinp and E ui ment within Secondary Containment <br /> 6.1 Flanged connection bolts tig t PIPING ON EAST SIDE OF THE TANK HAS PRODUCT RESIDUE AROUND IT. <br /> and fully engaged with no sign of <br /> wear or corrosion? ❑ Yes ❑X No. <br /> 7.0 Tank Roof <br /> 7.1 Standing water on roof? ❑ Yes ❑X No* <br /> 7.2 Evidence of coating cracking, <br /> crazing,peeling, blistering? ❑ Yes ❑X No* <br /> 7.3 moles in roof? ❑Yes ❑ X No* <br />
The URL can be used to link to this page
Your browser does not support the video tag.