My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-12-13_REVISION - M1980244 (63)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2019-12-13_REVISION - M1980244 (63)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2025 2:40:00 AM
Creation date
12/17/2019 8:37:50 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
12/13/2019
Doc Name Note
Appendix 11
Doc Name
Request For Amendment To Permit
From
CC&V
To
DRMS
Type & Sequence
AM13
Email Name
TC1
MAC
BFB
ERR
JPL
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br /> ACUREN <br /> Item Status comments <br /> 8.0 Venting <br /> 8.1 Vents free of obstructions? n Yes n X No* VENT IS BLINDED. <br /> 8.2 Emergency vent operable? <br /> Lift as required? uX Yes ❑ No' a NIA 12ND FILTER VENT IS IN GOOD CONDITION. <br /> 9.0 Insulated Tanks <br /> 9.1 Insulation missing? ❑Yes' ❑ No X NIA <br /> 9.2 Are there noticeable areas of <br /> moisture on the insulation? ❑Yes* ❑ No X NIA <br /> 9,3 Mold on insulation? ❑Yes' ❑ No X NIA <br /> 9.4 Insulation exhibiting damage? ❑Yes* ❑ No X NIA <br /> 9.5 Is the insulation sufficiently <br /> protected from water intrusion? nYes n No*X NIA <br /> 10.0 Level and Overfill Prevention Instrumentation of Sho -Fabricated Tanks <br /> 10.1 Has the tank liquid level <br /> sensing device been tested to <br /> ensure proper operation? a Yes ❑ X No* NIA ELECTRONIC LEVEL APPEARS TO BE IN GOOD CONDITION VERIFY ACCURACY. <br /> 10.2 Does the tank liquid level <br /> sensing device operate as <br /> req ui red? n Yes n No* X NII <br /> 10.3 Are overfill prevention <br /> devices in proper working <br /> condition? uYes a No' u X NIA <br /> 11.0 Electrical Equipment <br /> 11.0 Are tank grounding lines in <br /> good condition? n X Yes No* n NIA <br /> 11,2 Is electrical wiring for control <br /> boxesAi hts in good condition? u X Yes u No' a NIA <br /> RECOMMENDATIONS <br /> 1. REPAIR OR REPLACE FITTINGS THAT ARE LEAKING. <br /> 2. ENSURE PROPER VENTING IS BEING USED. <br /> 3. PERFORM PERIODIC INSPECTIONS AS OUTLINED IN STI-SPOO1. <br />
The URL can be used to link to this page