My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-11-18_INSPECTION - C1981035
DRMS
>
Day Forward
>
Inspection
>
Coal
>
C1981035
>
2019-11-18_INSPECTION - C1981035
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2024 2:18:52 PM
Creation date
11/18/2019 1:22:21 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981035
IBM Index Class Name
Inspection
Doc Date
11/18/2019
Doc Name
Inspection Report
From
DRMS
To
GCC Energy, LLC
Inspection Date
11/13/2019
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
November 13, 2019 C-1981-035/King Coal Mine LJW <br /> Inspection Topic Summary <br /> NOTE: Y=Inspected N=Not Inspected R=Comments Noted V=Violation Issued NA=Not Applicable <br /> N -Air Resource Protection Y -Roads <br /> N -Availability of Records N -Reclamation Success <br /> N -Backfill&Grading N -Revegetation <br /> N -Excess Spoil and Dev. Waste N - Subsidence <br /> N -Explosives N - Slides and Other Damage <br /> N -Fish&Wildlife N - Support Facilities On-site <br /> Y -Hydrologic Balance Y - Signs and Markers <br /> N -Gen. Compliance With Mine Plan N - Support Facilities Not On-site <br /> N -Other N - Special Categories Of Mining <br /> N -Processing Waste Y -Topsoil <br /> COMMENTS <br /> A partial inspection was conducted by Lucas West of DRMS on Wednesday November 13, 2019. Jordan <br /> McCourt of GCC accompanied Lucas in the field at King I and II. The Weather was clear and the ground was dry <br /> during the time of the inspection. Normal activities were being conducted during the inspection. At King 11, the <br /> stackers were actively moving mined material and trucks were being loaded. At King I waste material was being <br /> transferred and placed at the refuse pile. Also, construction activity was being conducted related to Technical <br /> Revision 27 (TR27) at the King I area. Six Photos accompany this report to illustrate the site conditions. <br /> HYDROLOGIC BALANCE -Rule 4.05 <br /> Drainage Control 4.05.1,4.05.2,4.05.3; Siltation Structures 4.05.5, 4.05.6; Discharge Structures 4.05.7,4.05.10; <br /> Diversions 4.05.4; Effluent Limits 4.05.2; Ground Water Monitoring 4.05.13; Surface Water Monitoring 4.05.13; <br /> Drainage—Acid and Toxic Materials 4.05.8; Impoundments 4.05.6, 4.05.9; Stream Buffer Zones 4.05.18: <br /> The hydrologic conveyances at King II were observed. Both the east and west clear water ditches were in <br /> excellent condition. All reaches of the water management system within the disturbed area boundary were <br /> functioning as designed at the time of the inspection. All culverts were unobstructed and in good condition. <br /> Examples of the ditches and Culverts can be seen in Photo One. Basin I was observed and can be seen in Photo <br /> Two. No signs of settling slumping or erosion were noted throughout the basin or in the entire water management <br /> system. <br /> At King I, construction of the new under drain system as approved through Technical Revision 27 was being <br /> conducted. The main reach of the underdrain was being installed and the lateral finger drains were staked out and <br /> ready to begin construction. The construction of the system was being done in accordance with the specifications <br /> and designs contained within TR27. Clearing work and road building was also being conducted to the west of the <br /> King I area to install the new western clear water ditch and access road as approved through TR27. Examples of <br /> the construction activity can be seen in Photos Three and Four. <br /> OTHER(SPECIFY): <br /> Along the eastern perimeter of the disturbed area at King II a small storage area is being used. Various <br /> Number of Partial Inspection this Fiscal Year: 3 <br /> Number of Complete Inspections this Fiscal Year: 2 <br /> Page 2 of 6 <br />