NEWMONT <br /> GOLDCORP <br /> materials will maintain sufficient transmissivity to provide active drainage towards <br /> the downstream Pregnant Storage Solution Area (PSSA). <br /> Although test results were slightly outside of the values set forth in the Technical <br /> Specifications, the material meet the intent of the design and were approved by the <br /> Certifying Engineer during construction. <br /> The "Project Deviations" section of the ROC report has been updated to capture <br /> these omissions. <br /> Additionally, Table 8 has been revised to: Remove the note "Sample numbers <br /> NFLDF-1-R through NFLDF-3-R (not shown in table) were submitted in previous <br /> Certification Reports",as this is not applicable to this table,and corrected the USCS <br /> Soil Identification of sample NFDCF-8-R to be GP-GC. <br /> 5. Table 8 — CQA Earthworks Testing Summary — Drain Cover Fill. Sample Numbers <br /> NFDCF-8-R, NFDCF-II-R, and NFDCF-I3-R have a Grain Size Distribution - Percent <br /> Passing of the No. 200 Sieve Size, greater than 8. Within 2.1 of the Earthworks Technical <br /> Specifications, the Percent Passing by Dry Weight of the No. 200 Sieve Size for Drain <br /> Cover Fill is 0 - 8. The Record of Construction Report states, within Section 3.2.4 Drain <br /> Cover Fill, that a total of seven DCF samples were tested with passing results.Additionally, <br /> as noted in Table 8, Sample Numbers NFDCF-8-R, NFDCF-II-R, and NFDCF-I3-R were <br /> approved by the Engineer of Record. Within Appendix H.4 - Drain Cover Fill Laboratory <br /> Test Results, the lab results show these three samples had greater than 8 Percent Passing <br /> of the No. 200 Sieve Size. Please address why these three samples were approved with <br /> an exceedance of the Technical Specifications. <br /> Similar to the previous comment, although the particle size distribution for a few <br /> select record tests of the DCF were outside the acceptable range,the materials were <br /> reviewed during construction and approved by the Certifying Engineer as they met <br /> the design intent and allowed by Section 2.1 of the Earthworks Technical <br /> Specification (Section 02200.0). <br /> Drawings: <br /> 6. Soil Liner Fill Asbuilt, Sheet Nos. 1. 2. and 3: The legend does not identify the X with the <br /> number next to it. Presumably this is a sequential survey point number. Regardless, these <br /> should be identified in the legend on each as-built drawing. Please submit updated <br /> drawings. <br /> The enclosed As-Built drawing has been updated. <br /> 7. High Volume Collection Pipe Asbuilts. Sheet Nos. 1. 2, and 3: The legend does not identify <br /> the X with the number next to it. Presumably this is a sequential survey point number. <br />