My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019-09-26_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2019-09-26_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 4:13:15 AM
Creation date
9/26/2019 3:01:36 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
9/26/2019
Doc Name
Water Monitoring - Groundwater
From
Holcum(US), Inc.
To
DRMS
Email Name
AME
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 <br /> Golder Associates ACZ Project ID: L52434 , <br /> L52434-04 NG475119 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data ' <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG474803 Cyanide,Free D6888-09/OIA-1677-09 MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits. ' <br /> WG474677 Mercury,dissolved M245.1 CVAA M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG474530 Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). , <br /> WG474739 Silver,dissolved M200.8 ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M200.8 ICP-MS RF Relative Percent Difference(RPD)for Ag in spiked <br /> samples exceeded limit. In the absence of HCI, ' <br /> precipitation of Ag may occur at different rates. <br /> M200.8 ICP-MS ZA Poor recovery for Silver quality control is accepted due to <br /> low Silver solubility in samples,digestates,or extracts that <br /> do not contain sufficient Hydrochloric acid. <br /> WG475119 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded ' <br /> calibration range. <br /> WG476400 Total Alkalinity SM2320B-Titration H1 Sample prep or analysis performed past holding time. See <br /> case narrative. <br /> WG474739 Vanadium,dissolved M200.8 ICP-MS BE Target analyte in continuing calibration blank(CCB)at or ' <br /> above the acceptance criteria. Target analyte was not <br /> detected in the sample[<MDL]. <br /> L52434-05 NG475119 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. ' <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> W G474803 Cyanide,Free D6888-09/OIA-1677-09 MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the ' <br /> acceptance limits. <br /> WG474677 Mercury,dissolved M245.1 CVAA M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG474530 Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated , <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG474739 Silver,dissolved M200.8 ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M200.8 ICP-MS RF Relative Percent Difference(RPD)for Ag in spiked ' <br /> samples exceeded limit. In the absence of HCI, <br /> precipitation of Ag may occur at different rates. <br /> M200.8 ICP-MS ZA Poor recovery for Silver quality control is accepted due to <br /> low Silver solubility in samples,digestates,or extracts that <br /> do not contain sufficient Hydrochloric acid. ' <br /> WG476400 Total Alkalinity SM2320B-Titration H1 Sample prep or analysis performed past holding time. See <br /> case narrative. <br /> REPAD.15.06.05.01 ' <br /> L52434-1908281443 Page 34 of 55 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.