' AOZ <br /> Laboratories, Inc. } <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 nx # <br /> SA <br /> ' Golder Associates ACZ Project ID: L52434 <br /> L52434-01 NG475119 Chloride M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> ' calibration range. <br /> M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> ' W G474803 Cyanide,Free D6888-09/OIA-1677-09 MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits. <br /> WG474677 Mercury,dissolved M245.1 CVAA M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> ' WG474530 Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG474775 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> ' validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG476400 Total Alkalinity SM2320B-Titration H1 Sample prep or analysis performed past holding time. See <br /> case narrative. <br /> L52434-02 NG475119 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> W G474803 Cyanide,Free D6888-09/OIA-1677-09 MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> ' acceptance limits. <br /> WG474677 Mercury,dissolved M245.1 CVAA M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG474530 Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> ' Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG474775 Residue,Filterable(TDS)@180C SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> ' WG475119 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> WG476400 Total Alkalinity SM2320B-Titration H1 Sample prep or analysis performed past holding time. See <br /> case narrative. <br /> ' L52434-03 NG475119 Chloride M300.0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> W G474803 Cyanide,Free D6888-09/OIA-1677-09 MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits;the RPD was within the <br /> acceptance limits. <br /> WG474677 Mercury,dissolved M245.1 CVAA M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> WG474530 Nitrite as N,dissolved M353.2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> ' Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> W G474739 Silver,dissolved M200.8 ICP-MS M2 Matrix spike recovery was low,the recovery of the <br /> associated control sample(LCS or LFB)was acceptable. <br /> M200.8 ICP-MS RF Relative Percent Difference(RPD)for Ag in spiked <br /> ' samples exceeded limit. In the absence of HCI, <br /> precipitation of Ag may occur at different rates. <br /> M200.8 ICP-MS ZA Poor recovery for Silver quality control is accepted due to <br /> low Silver solubility in samples,digestates,or extracts that <br /> do not contain sufficient Hydrochloric acid. <br /> ' WG475119 Sulfate M300.0-Ion Chromatography DC Sample required dilution. Non-target analyte exceeded <br /> calibration range. <br /> WG476400 Total Alkalinity SM2320B-Titration H1 Sample prep or analysis performed past holding time. See <br /> case narrative. <br /> ' REPAD.15.06.05.01 <br /> ' L52434-1908281443 Page 33 of 55 <br />