My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-10-30_REVISION - M1997027
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1997027
>
2018-10-30_REVISION - M1997027
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 3:22:45 AM
Creation date
10/30/2018 11:45:20 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1997027
IBM Index Class Name
REVISION
Doc Date
10/30/2018
Doc Name
Adequacy Review
From
Greg Lewicki & Assoc.
To
DRMS
Type & Sequence
TR2
Email Name
SJM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ASBESTOS and OTHER FIBERS by PCM:METHOD 7400,Issue 2,dated 15 August 1994-Page 3 of 15 <br /> EQUIPMENT(continued): <br /> 10.Acetone flash vaporization system for <br /> clearing filters on glass slides(see ref.[51 <br /> for specifications or see manufacturer's <br /> instructions for equivalent devices). <br /> 11.Micropipets or syringes,5-µL and 100-to <br /> 500-µL. <br /> 12.Microscope,positive phase(dark)contrast, <br /> with green or blue filter,adjustable field <br /> iris,8 to 10x eyepiece,and 40 to 45x phase <br /> objective(total magnification ca.400x); <br /> numerical aperture=0.65 to 0.75. <br /> 13.Graticule,Walton-Beckett type with 100-µm <br /> diameter circular field (area=0.00785 mm2) <br /> at the specimen plane(Type G-22).Available <br /> from Optometrics USA,P.O.Box 699,Ayer,MA <br /> 01432[phone(508)-772-1700],and McCrone <br /> Accessories and Components,850 Pasquinelli <br /> Drive,Westmont, IL 60559[phone(312) <br /> 887-71001. <br /> NOTE:The graticule is custom-made for each <br /> microscope.(see APPENDIX A for the <br /> custom-ordering procedure). <br /> 14. HSE/NPL phase contrast test slide,Mark II. <br /> Available from Optometrics USA(address <br /> above). <br /> 15.Telescope,ocular phase-ring centering. <br /> 16.Stage micrometer(0.01-mm divisions). <br /> SPECIAL PRECAUTIONS:Acetone is extremely flammable.Take precautions not to ignite it.Heating <br /> of acetone in volumes greater than 1 mL must be done in a ventilated laboratory fume hood using a <br /> flameless,spark-free heat source. <br /> SAMPLING: <br /> 1. Calibrate each personal sampling pump with a representative sampler in line. <br /> 2.To reduce contamination and to hold the cassette tightly together,seal the crease between the <br /> cassette base and the cowl with a shrink band or light colored adhesive tape. For personal sampling, <br /> fasten the(uncapped)open-face cassette to the worker's lapel.The open face should be oriented <br /> downward. <br /> NOTE:The cowl should be electrically grounded during area sampling,especially under conditions <br /> of low relative humidity.Use a hose clamp to secure one end of the wire(Equipment,Item 3) <br /> to the monitor's cowl.Connect the other end to an earth ground (i.e.,cold water pipe). <br /> 3. Submit at least two field blanks(or 10%of the total samples,whichever is greater)for each set of <br /> samples.Handle field blanks in a manner representative of actual handling of associated samples in <br /> the set.Open field blank cassettes at the same time as other cassettes just prior to sampling.Store <br /> top covers and cassettes in a clean area (e.g.,a closed bag or box)with the top covers from the <br /> sampling cassettes during the sampling period. <br /> 4. Sample at 0.5 L/min or greater[6].Adjust sampling flow rate,Q(L/min),and time,t(min),to produce <br /> a fiber density,E,of 100 to 1300 fibers/mm2(3.85x104 to 5x105 fibers per 25-mm filter with effective <br /> NIOSH Manual of Analytical Methods(NMAM),Fourth Edition <br />
The URL can be used to link to this page
Your browser does not support the video tag.