My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-08-22_REVISION - M1977493
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977493
>
2018-08-22_REVISION - M1977493
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2018 1:11:04 PM
Creation date
9/6/2018 12:53:42 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
Revision
Doc Date
8/22/2018
Doc Name Note
Part 1 of 3
Doc Name
Request for Technical Revision
From
Climax Molybdenum Company
To
DRMS
Type & Sequence
TR28
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Technical Revision (TR -28) Climax Molybdenum Company <br />Environmental Protection Plan Permit No. M-1977-493 <br />T-3.3.2 pH Adjustment (Lime) <br />Calcium Oxide (CaO), also known as lime or quicklime, is used in the water treatment circuit at Climax to <br />raise the pH and lower metal levels through precipitation. Lime also is used in reclamation operations <br />and at the mill to adjust the pH of process water. Lime is stored at the Lime Station, PDWTP and in small <br />stockpiles associated with current reclamation. Lime is a common, but strong caustic alkali. In high <br />concentrations, lime can cause caustic irritation, inflammation, and burns through inhalation and dermal <br />contact <br />Excessive amounts of lime in the environment can raise alkalinity to damaging levels. In aquatic systems, <br />excessive lime also can cause potentially damaging precipitation/sedimentation. <br />T-3.3.3 pH Adjustment (Sulfuric Acid) <br />Sulfuric acid (H2SO4) is used to adjust the pH of treated water at the PDWTP to within the permit <br />stipulated range of pH 6.5 - 9.0 prior to discharge to Tenmile Creek. Sulfuric acid is a corrosive that can <br />affect the human body through inhalation, ingestion, and dermal contact. Effects can vary from mild <br />irritations to severe burns (internally or externally) depending upon the type, degree, and length of <br />exposure. Repeated chronic exposure to dilute solutions may cause dermal irritations, whereas similar <br />exposure to vapors or mists may cause erosion of teeth and inflammation of the eyes and mucus <br />membranes of the nose, throat, and lungs. <br />In the environment, sulfuric acid can be directly toxic through its corrosive nature or by lowering pH levels <br />to the point of toxicity. In addition, even in very dilute forms, which may not be injurious to human health, <br />chronic releases of sulfuric acid can dissolve metals from rocks which, in turn, can damage aquatic and, <br />in some instances, terrestrial ecosystems. Sulfuric acid is readily neutralized by the addition of alkaline <br />substances such as NaOH, CaO, or limestone. <br />T-3.4 Safety Data Sheets for Designated Chemicals <br />Safety Data Sheets (SDS) are attached in Appendix T -B. Updated SDSs are maintained at the site. <br />These data sheets list permissible exposure limits, monitoring and measurement procedures, health <br />hazard information and exposure effects, recommended medical procedures for human exposure, <br />emergency first aid procedures, personal protection, leak and spill procedures, and waste disposal <br />methods. <br />T-3.5 Disposal, Decommissioning, Detoxification or Stabilization <br />Procedures for the disposal, decommissioning, detoxification or stabilization of designated chemicals <br />during temporary cessation or final closure are discussed in the following sections. <br />T-3.5.1 Temporary Cessation/Prolonged Lack of Mineral Production <br />Under the scenario of formal temporary cessation or periods of prolonged lack of mineral extraction and <br />production, designated chemicals at Climax would be used or removed from the site. Mixed chemicals <br />such as Nokes Reagent and NaCN in solution would be used in the milling process until depletion of the <br />supplies. The distributor would be contacted to assume possession of unmixed and uncontaminated <br />chemicals, and the material would be transported off-site in the same manner that it was received at the <br />site. Those designated chemicals used in the water treatment system at Climax would remain at the site <br />and would continue to be used. Water treatment and discharge would not cease under these scenarios. <br />If unmixed chemicals were contaminated or the distributors were to decline possession, then <br />detoxification or stabilization and disposal would be managed pursuant to solid and hazardous waste <br />regulations. <br />T-3.5.2 Final Closure <br />Upon final closure at the conclusion of operations at Climax, designated chemicals will be handled in <br />similar fashion as under the scenario described above. The exception is that lime, sulfuric acid, and <br />EPP: Version R4 T-14 August 2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.