My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-03-09_PERMIT FILE - M2017049 (29)
DRMS
>
Day Forward
>
Permit File
>
Minerals
>
M2017049
>
2018-03-09_PERMIT FILE - M2017049 (29)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2021 11:47:59 PM
Creation date
3/9/2018 3:38:32 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2017049
IBM Index Class Name
PERMIT FILE
Doc Date
3/9/2018
Doc Name Note
PART 1 OF 3
Doc Name
Adequacy Review Response
From
Transit Mix Concrete Co.
To
DRMS
Permit Index Doc Type
Application Materials
Email Name
TC1
ERR
ECS
WHE
AME
PSH
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Transit Mix Concrete Co. <br /> Response: Transit Mix commits to collecting the geotechnical information and revising the <br /> geotechnical assessment with the site-specific information. Transit Mix will submit for <br /> Division review the data and results as a technical revision or amendment. <br /> 15. As stated in the Recommendations section of Hitch Rack Ranch Quarry Waste Stockpile <br /> Stability Analyses, dated August 29, 2017, please commit to reviewing and revising the <br /> engineering designs using the site specific data as needed prior to construction, and <br /> submit the engineering designs report for Division review and approval through either the <br /> technical revision or amendment process, to occur subsequent to the issuance of the <br /> permit. <br /> Response: Transit Mix commits to revising the geotechnical assessment with the site- <br /> specific information. Transit Mix will submit for Division review the data and results as a <br /> technical revision or amendment. <br /> 16. As stated in the Recommendations section of Hitch Rack Ranch Quarry Waste Stockpile <br /> Stability Analyses, dated August 29, 2017, please commit to managing the upstream <br /> surface water run-on above the stockpile to limit infiltration and erosion, and submit all <br /> changes to the water management plan for Division review and approval through either <br /> the technical revision or amendment process, to occur subsequent to the issuance of the <br /> permit. <br /> Response: Transit Mix commits to managing upstream surface run-on to limit erosion and <br /> infiltration. Transit Mix will submit any changes in the water management system to the <br /> Division as a technical revision or amendment. <br /> 17. As stated in the Recommendations section of Hitch Rack Ranch Quarry Waste Stockpile <br /> Stability Analyses, dated August 29, 2017, please commit to reviewing and updating the <br /> stability analysis to evaluate the difference in parameters and determine any adjustments <br /> to the analysis once the final site conditions, construction design, placement method, and <br /> monitoring plans are in place, and submit the updated stability analysis report for <br /> Division review and approval through either the technical revision or amendment <br /> process, to occur subsequent to the issuance of the permit. <br /> Response: Transit Mix commits to revising the geotechnical assessment with the site- <br /> specific information, final site conditions, construction details, and monitoring plans and <br /> submitting the information to the Division for review as a technical revision or amendment. <br /> Hitch Rack Ranch Pit Wall Geotechnical Assessment: <br /> 18. In 3.7.2 Faulting section of the geotechnical assessment, the Applicant states additional <br /> mapping and drilling is a requirement as the quarry design is advanced in order to <br /> confirm the orientation and quality of the seams/potential faults and the effect on pit wall <br /> design through the various pit phases. Please commit to performing the additional <br /> mapping and drilling to evaluate the effects of the faulting on the highwall stability. <br /> Hitch Rack Ranch Quarry(M-2017-049) <br /> Response to Comments—March 9,2018 <br />