Laserfiche WebLink
ADZ Laboratories, Inc. Inorganic Extended <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 Qualifier Report <br /> Golder Associates ACZ Project ID: L41229 <br /> L41229-05 JVG437911 Chloride M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> M300 0-Ion Chromatography H2 Initial analysis within holding time Reanalysis for the <br /> required dilution was past holding time <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG436377 Residue,Filterable(TDS)@180C SM2540C RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density <br /> exceeded the method limits Another duplicate in the batch <br /> was used to assess precision Method required duplicate <br /> frequency was not met <br /> WG437312 Sodium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG437911 Sulfate M300 0-Ion Chromatography H2 Initial analysis within holding time Reanalysis for the <br /> required dilution was past holding time <br /> WG436792 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> L41229-06 VVG437911 Chloride M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG436440 Residue,Filterable(TDS)@180C SM2540C RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density <br /> exceeded the method limits Another duplicate in the batch <br /> was used to assess precision Method required duplicate <br /> frequency was not met <br /> WG437312 Sodium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG437911 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> WG436792 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> L41229-07 VVG437911 Chloride M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG436440 Residue,Filterable(TDS)@180C SM2540C RO The duplicate originally assigned to this sample was not <br /> used for precision assessment because residue density <br /> exceeded the method limits Another duplicate in the batch <br /> was used to assess precision Method required duplicate <br /> frequency was not met <br /> WG437312 Sodium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG437911 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> WG436792 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> L41229-08 VVG437911 Chloride M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG437312 Sodium,dissolved M200 7 ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level The recovery of the associated control sample(LCS <br /> or LFB)was acceptable <br /> WG436792 Total Alkalinity SM2320B-Titration RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> REPAD 15 06 05.01 <br /> L41229-1712200847 Page 18 of 25 <br />