My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-03-23_REPORT - M1988112
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1988112
>
2017-03-23_REPORT - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2020 10:52:38 PM
Creation date
3/24/2017 12:04:58 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
REPORT
Doc Date
3/23/2017
Doc Name
Annual Fee/Report/Map
From
Battle Mountain Resources, Inc.
To
DRMS
Annual Report Year
2017
Email Name
WHE
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
As reported in the 2015 second annual inspection report. the three, 8-inch diameter sub-drain pipe outlets <br /> were uncovered again in August 2014, and the pipes were cleaned by jetting and a camera inspection was <br /> completed on August 19, 2014. The camera inspection report was attached with the 2015 annual <br /> inspection report. All three pipes were flowing at the time of the camera inspection. and all three were <br /> found to be partially collapsed at vamim, distances up-gradient from the outlets, Although partially <br /> collapsed, the pipes are conveying water collected by the gra-vel underdrain system that sits above the <br /> liner. Based on analyses performed as part of the Detailed Inspection Report (MGC, 2014) phreatic <br /> conditions within the dam embankment are anticipated to remain IoNv and static factors of safety <br /> unchanged even with the pipes fully blocked. Because the pipes are flowing and observed llok%, rates are <br /> consistent with historic readings,the damage to the pipes is not considered to be a dam safety concern. <br /> To prevent blockage of the sub-drain collection pipe discharge area by surface sloughing at the toe of the <br /> dam. in 2014 the three pipes were connected to a manifold and the combined pipe flows are conveyed by <br /> it single pipe extension from the manifold at the dam toe to the downstream pump-back pond. *I he <br /> underdrain collection pipe manil'old/extension appears to have been effective in reducing seepage <br /> emerging on the downstream toe of the dam in the%icinity of the pipes. At the time of this 2016 inspection <br /> the slope above the pipes remains dr), but there was sonic pending of water in the vicinity of the pipe <br /> outt'alls(see Photo 12)that mat be due to surface water and some rninor leakage from one or more of the <br /> sub-drain pipes up-gradient graded from the manifold. It is recommended that this area he <br /> L, graded and backfilled <br /> to reduce pending of surface water at the dam toe in the vicinity of the` pipe outkills <br /> The Detailed Inspection Report (M(;C 2014) included recommendations for design of improvements to <br /> the South Diversion Ditch and drop structure to minimize risk to the dam during major flood events. In <br /> 2015 to early 2016, MGC completed hydrologic and geotechnical studies and prepared final engineering <br /> design,construction drawings and technical specifications for a project that will substantially increase the <br /> hydraulic capacity of the South Diversion [)itch. The project includes improvements to the channel and <br /> replacement of the existing conduit drop structure with a more robust reinforced concrete drop structure <br /> at the left dam abutment. It is recommended that the South Di-version Ditch system improvements be <br /> constructed as--,()oil as funding can be secured. <br /> I he overall condition of the dam is -Conditionally Satisfactory". pending construction of improvements <br /> for the South Diversion [)itch and replacement of.the drop structure. Please feel free to contact us if you <br /> have any questions regarding this report. <br /> Regards, <br /> Debora J. Miller, Ph.D., P.F.. <br /> MILLER GE"OTEOINICAl. CONSULTANTS, INC. <br /> 2 <br /> 2016 Dam Safety Inspection Report San Luis Tailings Dam <br />