PART 3 — EXECUTION <br />3.1 GENERAL <br />A. Construct straight joints; make vertical or horizontal, except where walls intersect sloping <br />floors. <br />B. Commence concrete placement after the joint preparation is complete. <br />3.2 SURFACE PREPARATION <br />A. Construction Joints: <br />1. Remove all laitance, and foreign substances (including curing compound) from: <br />concrete surface, water stop, and reinforcing steel. <br />2. Roughen concrete surface to a minimum of'/ -inch amplitude: <br />a. Sandblast after the concrete has fully cured. <br />b. Water blast after the concrete has partially cured. <br />c. Green cut fresh concrete with high pressure water and hand tools. <br />d. Protect water stop from damage, if one is present. <br />3. Wash surfaces with clean water. <br />4. Coat surfaces with an epoxy bonding compound prepared and applied as <br />recommended by the manufacturer. <br />B. Expansion Joint with Pourable Filler: <br />1. Use motorized wire brush or other motorized device to mechanically roughen and <br />thoroughly clean concrete surfaces on each side of joint from plastic water stop to the <br />top of the joint. <br />2. Use clean and dry high pressure air to remove dust and foreign material, and dry <br />joint. <br />3. Prime surfaces before placing joint filler. <br />4. Avoid damage to water stop. <br />C. Expansion Joint without Pourable Filler: <br />1. Coat concrete surfaces above and below plastic water stop with bond breaker. <br />2. Do not damage water stop. <br />D. Control Joint. <br />1. Coat concrete surfaces above and below plastic water stop with bond breaker. <br />2. Do not damage water stop. <br />Expansion, Construction and Control Joints February 2017 03251-5 <br />