Laserfiche WebLink
Newmont‐Cripple Creek & Victor Gold Mine  <br />Technical Specification No. 02200.DOCX  <br />Squaw Gulch VLF  <br />Project No.475.0106.006  <br />June 15, 2016  <br />  <br />  <br />  <br />Page 3  <br />3. Underdrain  Fill  ‐  granular,  material  approved  by MANAGER and CERTIFYING  <br />ENGINEER conforming to the following SPECIFICATION.  <br />  <br />U.S. Standard  <br />Sieve Size  <br />Percent Passing  <br />by Dry Weight  <br />12‐inch  100  <br />No. 200  0 – 6  <br />Point load tensile strength:  > 300 psi  <br />Plasticity Index: 0  <br />  <br />4. Leak Detection Fill ‐ material approved by MANAGER and CERTIFYING ENGINEER  <br />conforming to the following SPECIFICATION:  <br />  <br />U.S. Standard  <br />Sieve Size  <br />Percent Passing  <br />by Dry Weight  <br />1‐inch  100  <br />⅜‐inch  40 – 70  <br />No. 4  5 – 50  <br />No. 40  0 – 20  <br />No. 200  0 – 10  <br />Plasticity Index: 0  <br />  <br />5. Low  Volume  Solution  Collection  Fill  and  Bedding  Fill  ‐  material approved by  <br />MANAGER and CERTIFYING ENGINEER conforming to the following SPECIFICATION:  <br />  <br />U.S. Standard  <br />Sieve Size  <br />Percent Passing  <br />by Dry Weight  <br />1‐inch  100  <br />⅜‐inch  40 – 70  <br />No. 4  5 – 55  <br />No. 200  0 – 10  <br />Plasticity Index: 0  <br />  <br />