Newmont‐Cripple Creek & Victor Gold Mine  <br />Technical Specification No. 02710.DOCX  <br />Squaw Gulch VLF  <br />Project No.475.0106.006  <br />June 15, 2016  <br />  <br />  <br />  <br />Page 3  <br />C. Piping shall be placed to the lines and elevations shown on the DRAWINGS, with no sags  <br />or humps, as approved by MANAGER and CERTIFYING ENGINEER.    <br />3.2. Pipe Connections  <br />A. All  connections  for  non‐perforated  pipe  shall  be  watertight  under  maximum  <br />anticipated pressure head.  <br />B. The ends of all pipe shall be capped with a manufactured pipe cap.  <br />C. HDPE pipe will be butt‐heat‐fusion welded in accordance with the MANUFACTURER's  <br />guidelines.  <br />D. CPe pipe joints shall conform to MANUFACTURER's recommendations.  <br />3.3. Bedding and Backfill  <br />A. CONTRACTOR shall  place  and  compact  Leak  Detection  Fill  in  accordance  with Item  <br />3.06.E of Section 02200.0.  <br />B. CONTRACTOR shall bed and backfill Leak Detection piping with Leak Detection Fill.  <br />C. Low Volume and High Volume Solution Collection pipe shall be placed on top of the  <br />geosynthetics, as shown on the DRAWINGS.  <br />D. Placement  of  Low  Volume  and  High  Volume  Solution  Collection  and High Volume  <br />Solution  Collection  pipes  shall be  coordinated  with  other  operations  such  as  Low  <br />Volume Solution Collection Fill, Bedding Fill, Soil Liner, and Drain Cover fill placement.  <br />Equipment access directly on geosynthetics is expressly prohibited. Any damage to the  <br />geosynthetics caused by CONTRACTOR during pipe placement shall be repaired at the  <br />expense of CONTRACTOR.  <br />E. A minimum of 5 feet of Low Volume Solution Collection Fill and Drain Cover Fill shall be  <br />placed  over  the  top  of  the  pipe  before  crossing  with  rubber‐tired  construction  <br />equipment.  If  pipe  becomes  crushed  during  or  after  installation by CONTRACTOR's  <br />equipment or methods of construction, the pipe shall be replaced by CONTRACTOR, at  <br />no  additional  cost  to CC&V.  The CONTRACTOR will  be  required  to demonstrate  to  <br />MANAGER that the equipment and procedures used are not detrimental to the piping,  <br />at no additional cost to CC&V.  <br />F. CONTRACTOR shall hold pipes in place with sand bags, or other methods approved by  <br />MANAGER, until the Low Volume Solution Collection Fill and Drain Cover Fill has been  <br />placed. Directly before placement of the Low Volume Solution Collection Fill and Drain  <br />Cover Fill, the sand bags will be removed.  <br />G. Secondary or tertiary High Volume Solution Collection pipes will be attached to the  <br />primary  pipes  with  plastic  ties  or  other  method  approved  by MANAGER and  <br />CERTIFYING ENGINEER.